Rmtest-Rs232 Interface Test Program - Network Technologies UNIMUX series Installation And Operation Manual

Unimux series high density vga usb kvm switch
Table of Contents

Advertisement

NTI UNIMUX SINGLE-USER HIGH DENSITY VGA USB KVM SWITCH

RMTEST-RS232 Interface Test Program

This software also allows a user to test the functions of an NTI server switch, matrix switch or Multi-user/Multi-platform switch
RS232 interface. The RMTEST program is automatically loaded when installing the NTI Switch Control Program as described on
page 34. The RMTEST program, located in the NTI program group, generates a main menu with the 3 selections described
below:
MAIN OPTIONS
1. Matrix Options
- send commands to the matrix unit.
2. Setup Options
- set COM port, baud rate, and unit address
3. Quit
- quit the program
If Matrix Options is selected, the following menu, which has 7 options, is displayed:
MATRIX OPTIONS
1. Reset single unit
2. Reset all units
3. Change single output
4. Change all outputs
5. Read single output
6. Read unit size
7. Return to main menu
The Setup Options main menu selection only needs to be executed if the switches baud rate or unit address have been changed
from the factory defaults ( 9600 baud, and unit address = 1). When this option is selected, the following menu, which has 4
options, is displayed:
SETUP OPTIONS
1. Set COM port (default = COM1)
2. Set baud rate (default = 9600)
3. Set unit address (default = 01)
4. Return to main menu
For any selection that requires user input, the user is prompted. When commands are sent to the matrix unit, the command string
and matrix unit responses are echoed to the screen. All commands generated by the program are formatted according to the
information provided in the sections above. If any transmission problems are detected, an error message is displayed.
- reset single matrix to power-up defaults (matrix switch only)
- reset all daisy chained matrix units (matrix switch only)
- connect an input to one output
- connect an input to all outputs
- read which input is connected to an output
- read how many inputs and outputs the unit has
- go back to the MAIN OPTIONS menu
- set port to COM1-COM3
- set baud rate (see interface manual for supported baud rates)
- set the unit address (if multiple units are daisy-chained)
- Go back to the MAIN OPTIONS menu