OCX 8800
1-10
Specifications
Sensors Housing
Electronics Housing
Electrical Noise
Certifications
Line Voltage
Pollution Degree
Over Voltage Category
Relative Humidity
Isolated Output
Oxygen
Combustibles
Alarm
Power Consumption
NOTE
All static performance characteristics are with operating variables constant. Specifications subject to change
without notice.
NEMA 4, IP66 with fitting and pipe on reference exhaust port to
clean, dry atmosphere, two 3/4-14 NPT conduit ports
NEMA 4, IP66 with fitting and pipe on reference exhaust port to
clean, dry atmosphere, two 3/4-14 NPT conduit ports
EN 61326-1, Class A
Sensor Housing
0344
II 2 G
2005.1602514
KEMA 04 ATEX 2308
CLASS 1, ZONE 1
EEx d IIB+H2 T3
Ex d IIB+H2 T3
AEx D IIB+H2 T3
TYPE 4 / IP66
Electronics Housing
0344
II 2 G
2005.1602514
KEMA 04 ATEX 2308
CLASS 1, ZONE 1
EEx d IIB+H2 T6
IP66
Ex d IIB+H2 T6
AEx D IIB+H2 T6
TYPE 4 / IP66
Universal 100 to 240 VAC ±10%, 50 to 60 Hz, no switches or
jumpers required, 3/4-14 NPT conduit port
2
II
5 to 95% (non-condensing)
4-20 mAdc, 950 ohm maximum, with HART capability
4-20 mAdc, 950 ohm maximum
Alarm output relay - dry contact, form C, 30 mA, 30VDC capacity
750 W maximum
Instruction Manual
IM-106-880, Rev 1.0
January 2007
C
US
APPROVED
CLASS 1, ZONE 1
AEx D IIB+H2 T3
TYPE 4 / IP66
C
US
APPROVED
CLASS 1, ZONE 1
AEx D IIB+H2 T3
TYPE 4 / IP66