Figure 2-6. Oxymitter 4000 Adapter Plate Installation - Emerson Oxymitter 4000 Instruction Manual

Oxygen transmitter
Table of Contents

Advertisement

Oxymitter 4000
INSTALLATION FOR METAL
WALL STACK OR DUCT
CONSTRUCTION
MTG HOLES
SHOWN ROTATED
45 OUT OF
o
TRUE POSITION
WELD OR BOLT ADAPTER
PLATE TO METAL WALL
OF STACK OR DUCT.
JOINT MUST BE AIRTIGHT.
WELD OR BOLT ADAPTER
PLATE TO METAL WALL
OF STACK OR DUCT.
JOINT MUST BE AIRTIGHT.
Rosemount Analytical Inc.
A Division of Emerson Process Management
0.50 [13]
3.75 [95]
MIN DIA HOLE
IN WALL
STACK OR DUCT
METAL WALL
2.50 [63.5]
MIN DIA HOLE
IN WALL
STACK OR DUCT
METAL WALL
NOTE: DIMENSIONS IN INCHES WITH
MILLIMETERS IN PARENTHESES.

Figure 2-6. Oxymitter 4000 Adapter Plate Installation

INSTALLATION FOR MASONRY
WALL STACK CONSTRUCTION
BOLT ADAPTER
PLATE TO OUTSIDE
WALL SURFACE
FIELD WELD
PIPE TO
ADAPTER PLATE
MTG HOLES
SHOWN ROTATED
o
45 OUT OF
TRUE POSITION
JOINT MUST
BE AIRTIGHT
OUTSIDE WALL
SURFACE
NOTE: ALL MASONRY STACK WORK AND JOINTS EXCEPT
ADAPTER PLATE NOT FURNISHED BY ROSEMOUNT.
BOLT ADAPTER
PLATE TO OUTSIDE
WALL SURFACE
JOINT MUST
BE AIRTIGHT
OUTSIDE WALL
SURFACE
Instruction Manual
IB-106-340 Rev. 3.0
December 2003
0.50 [13]
4.50 [114]
O.D. REF
PIPE 4.00 SCHED 40
PIPE SLEEVE (NOT
BY ROSEMOUNT)
LENGTH BY CUSTOMER
MASONRY
STACK WALL
FIELD WELD
PIPE TO
ADAPTER PLATE
3.50 [89]
O.D. REF
PIPE 3.00 SCHED 40
PIPE SLEEVE (NOT
BY ROSEMOUNT)
LENGTH BY CUSTOMER
MASONRY
STACK WALL
35830005
Installation
2-7