Table 1-2. Calibration Components - Emerson Oxymitter 4000 Instruction Manual

Oxygen transmitter
Table of Contents

Advertisement

Oxymitter 4000
Cont'd
Code
Communications
1
HART with Membrane Keypad, blind cover
2
HART with Membrane Keypad, glass cover
3
HART with Local Operator Interface, glass cover, English only
Code
1
2
3
4
5
Cont'd
2
2
NOTES:
(1)
Recommended usages: High velocity particulates in flue stream, installation within 11.5 ft (3.5 m) of soot blowers or heavy salt cake buildup.
Applications: Pulverized coal, recovery boilers, lime kiln. Regardless of application, abrasive shields with support brackets are recommended
for 9 ft (2.74 m), 12 ft (3.66 m), 15 ft (4.57 m), and 18 ft (5.49 m) probe installations, particularly horizontal installations.
(2)
Where possible, specify SPS number; otherwise, provide details of the existing mounting plate as follows:
Plate with studs
Bolt circle diameter, number, and arrangement of studs, stud thread, stud height above mounting plate.
Plate without studs
Bolt circle diameter, number, and arrangement of holes, thread, depth of stud mounting plate with accessories.
Part Number
1A99119G01
1A99119G02
1A99119G03
* Calibration gas bottles cannot be shipped via airfreight. When bottles are used with "CALIBRATION RECOMMENDED" features,
the bottles should provide 2 to 3 years of calibrations in normal service.
Rosemount Analytical Inc.
A Division of Emerson Process Management
Table 1-1. Product Matrix (Continued)
Language
English
German
French
Spanish
Italian
Code
Filtered Customer Termination
00
Specified as Part of Electronics Housing
Code
Calibration Accessories
00
No Hardware
01
Calibration Gas Flowmeter and Reference Air Set
02
Intelligent Multiprobe Sequencer (Refer to Table 1-3)
03
Single Probe Sequencer, Horizontal Orientation, Brass/Teflon, no Reference Air Set
04
Single Probe Sequencer, Horizontal Orientation, Brass/Teflon, with Reference Air Set
05
Single Probe Sequencer, Horizontal Orientation, Stainless Steel, no Reference Air Set
06
Single Probe Sequencer, Horizontal Orientation, Stainless Steel, with Reference Air Set
07
Single Probe Sequencer, Vertical Orientation, Brass/Teflon, no Reference Air Set
08
Single Probe Sequencer, Vertical Orientation, Brass/Teflon, with Reference Air Set
09
Single Probe Sequencer, Vertical Orientation, Stainless Steel, no Reference Air Set
10
Single Probe Sequencer, Vertical Orientation, Stainless Steel, with Reference Air Set
Code
00
10
11
12
13
14
15
16
14
00
09

Table 1-2. Calibration Components

Two disposable gas bottles — 0.4% and 8% O
Two flow regulators for calibration gas bottles
Bottle rack
Electronics to Probe Cable Length
No Cable
20 ft (6 m) Cable
40 ft (12 m) Cable
60 ft (18 m) Cable
80 ft (24 m) Cable
100 ft (30 m) Cable
150 ft (45 m) Cable
200 ft (61 m) Cable
Description
, balance nitrogen — 550 liters each*
2
Instruction Manual
IB-106-340 Rev. 3.0
December 2003
Example
Description and Specifications