H1/7
RED/WHITE
This wire produces a (-) 200mA output for progressive locks in which the driver
door unlocks first and the remaining locks unlock with a second press of the
unlock button.
H1/8
BLACK
Remove any paint and connect this wire to bare metal, preferably with a fac-
tory bolt rather than your own screw. (Screws tend to either strip or loosen with
time.) We recommend grounding all your com po nents to the same point in the
vehicle.
20
CHANNEL 2, (-) 200mA OUTPUT
Warning! Never use this wire to drive anything
but a relay or a low-current input, supplied out-
put is only 200mA. Connecting directly to a
solenoid, motor, or other high-current device
will cause the module to fail.
(-) CHASSIS GROUND CONNECTION