Environmental Requirements - Smart Technologies SMART Board 480i5 User Manual

Interactive whiteboard system
Hide thumbs Also See for SMART Board 480i5:
Table of Contents

Advertisement

I M P O R T A N T I N F O R M A T I O N

Environmental requirements

Before installing your SMART Board 480i5 interactive whiteboard system, review the following
environmental requirements.
Environmental
requirement
Operating temperature
Storage temperature
Humidity
Water and fluid
resistance
Dust
Electrostatic discharge
(ESD)
Cables
Conducted and radiated
emissions
v
Parameter
5°C to 35°C (41°F to 95°F) from 0 m to 1800 m (0' to 6000')
l
-20°C to 40°C (-4°F to 104°F)
l
30% to 80% relative humidity, non-condensing
l
Intended for indoor use only. Doesn't meet any salt-spray or water
l
ingress requirements.
Don't pour or spray liquids directly onto your interactive whiteboard,
l
the SMART UF75 projector or any of its sub-components.
Designed for pollution degree 1 (P1) as per EN61558-1, which is
l
defined as "No pollution or only dry non-conductive pollution"
EN61000-4-2 severity level 4 for direct and indirect ESD
l
No malfunction or damage up to 8kV (both polarities) with a 330
l
ohm, 150 pF probe (air discharge)
Unmated connectors meet no malfunction or damage up to 4kV
l
(both polarities) for direct (contact) discharge
All SMART Board 480i5 interactive whiteboard system cables
l
should be shielded to prevent potential accidents and degraded
video and audio quality.
EN55022/CISPR 22, Class A
l

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smart board 480Smart uf75

Table of Contents