Connecting The Dc Positioning Drive To The Mains Voltage; Connecting The Sewing Machine Head - Duerkopp Adler 869 Instruction Manual

Hide thumbs Also See for 869:
Table of Contents

Advertisement

11.5 Connecting the DC positioning drive to the mains voltage

11.5.1

Connecting the sewing machine head

Caution!
A pluggable connection must be used to connect the sewing machine
to the mains supply voltage!
The DC positioning drive is run with single-phase AC current of
190 - 240V 50/60Hz. The connection should be made according to the
connection diagram 9800 120009 A or 9800 130014 R.
When connecting to a three-phase supply of 3x380V, 3x400V or
3x415V, the sewing drive should be connected to one phase and to a
neutral conductor.
When connecting to a three-phase supply of 3x200V, 3x220V, 3x230V
or 3x240V, the sewing drive should be connected to two of the phases.
If multiple DC positioning drives need to be connected to the same
three-phase supply, you should distribute the connections amongst all
of the phases equally so that no single phase is overloaded.
The cable numbered 9870 867000 is plugged into the head
distributor 9850 867000. This cable is then routed downwards
inside the head.
The 37-pole plug on the cable should be connected and screwed in
to socket A on the sewing drive.
GB
33

Advertisement