Set-up instructions

8.14.3 Connecting the direct drive

To do this, read the DAC operating manual, basic/classic.
Connecting the direct drive consists of the following work:
• Insert the plugs of all connecting cables in the sockets on the back of
• Connect the cable for equipotential bonding.
• Connect the control to the power supply using the power cable.

8.15 Pneumatic connection

8.15.1 Fitting the maintenance unit

The pneumatic unit is an additional component that is not part of the stan-
dard delivery package.
(1) - Machine tube
(2) - Maintenance unit
Figure 48: Connecting the pneumatic unit
• Attach the maintenance unit (2) to the upper cross bar (4) of the frame
• Connect the machine tube (1) coming out of the upper section to the
• Connect the system connection tube (3) to the pneumatic system.
Operating manual H867 Version 00.0 - Last updated: 01/2012
the control.
ATTENTION
Machine damage possible due to incorrect pressure.
An incorrect pressure can cause damage to the machine.
The system pressure for the pneumatic unit is 8 - 10 bar.
Make sure that the system pressure is set correctly before fitting the
pneumatic unit.
r
e
using the bracket, screws and clip.
maintenance unit (2) at the top right.
6
4
8
2
10
0
(3) - System connection tube
(4) - Cross bar