10.4 Mounting the sewing light (optional equipment)

6
7
CAUTION !
The power supply to the sewing light is not disconnected when the
main switch is turned off. Remember to pull out the mains plug before
making this connection.
2
1
The sewing light 1 will be mounted on the arm cover 2.
Screw off the arm cover 2.
Use a 4.5-mm Ø bit to drill the fastening holes 3.
Screw the retainer piece 5 using screw 4.
Put the sticker with the safety notice on the front of the main
switch 7.
Put the sewing light onto the retainer piece 5.
Unscrew the valve cap 6.
Route the sewing light's supply cable into the cut-out on the
machine arm.
Guide the the connection cable downwards through the opening in
the table plate.
Fasten the sewing light transformer under the table plate using
particle-board screws.
Plug in the connector for the transformer's power supply.
Put on the cover 2 and valve cap 6.
2
5
4
3
GB
27