INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
MOUNTING RECOMMENDATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
PREPARATION INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
FAN INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
CONTROL FEATURES:
3-SPEED OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Safety and the proper operation of your Casablanca fan both require a thorough knowledge of the
product and proper installation; therefore, before attempting to install and operate your Casablanca
fan, read this owner's manual completely and carefully. Retain this manual for future reference.
CAUTION: To avoid possible electrical shock, make certain that electricity is turned off
at the circuit breaker or fuse box before attempting any installation procedure.
• All wiring must be in accordance with the National Electric Code ANSI/NFPA 70-1993 and the appropriate local electrical
codes. The National Electric Code requires proper grounding as a precaution against electrical shock. A qualified electri-
cian should be consulted if you are unsure.
• This fan is designed to be installed on an existing electrical outlet box. The outlet box must be UL Listed for ceiling fan
installations, if it is not, a new box must be installed. Casablanca extension poles are available for sloped or high ceiling
installations.
• This ceiling fan requires a grounded electrical supply of 120 VAC, 60 Hz and a minimum 15 amp circuit. The maximum
current requirement for the fan with light fixture is 3.8 amps. The fan uses about 1 amp or 100 watts. Maximum light
current is 2.8 amps or 340 watts of lighting.
• Where wire nuts are employed, be sure all bare wires are within the connectors. When installing the canopy hatch, make
sure all wires are within the canopy and that no wires are being pinched.
use only genuine Casablanca blades, light fixtures, and accessories.
• The blades in each pack are matched for equal
weight to assure smooth fan operation. If
more than one fan is being installed, be
careful not to mix blades from different
cartons.
• Inspect the contents of your carton for
possible shipping or handling damage and
report any such damage directly to your
authorized Casablanca dealer.
• It is always a good idea to have an assistant
to help with the installation.
• When cleaning, painting, or working near
your fan, be very careful of the fan and blades.
Always turn the power OFF to the ceiling fan
before servicing it, working on it, or replacing
light bulbs.
• Never insert anything into the path of the
fan blades while the fan is in operation.
• Never install a fan over a pool or spa.
• Never operate a fan that has been damaged
in any way. Contact Casablanca Fan Company
by calling toll free 1-888-227-2178, or
contact your local authorized Casablanca
dealer for assistance in obtaining service.
CONTENTS
READ AND SAVE THESE INSTRUCTIONS

SAFETY FIRST

BEFORE YOU START

For best performance and for your warranty to be valid,

SAFE USE

(REMOVE FUSE FOR THE
CIRCUIT YOU WILL BE
WORKING ON)
CIRCUIT BREAKER
(TRIP BREAKER FOR THE
CIRCUIT YOU WILL BE
WORKING ON)
PN 7743010 AT0508
FUSE BOX
18
70
84
1

Advertisement

Table of Contents
loading

Summary of Contents for Casablanca UTOPIAN

  • Page 1: Table Of Contents

    • Never install a fan over a pool or spa. • Never operate a fan that has been damaged in any way. Contact Casablanca Fan Company by calling toll free 1-888-227-2178, or contact your local authorized Casablanca dealer for assistance in obtaining service.
  • Page 2: Mounting Recommendations

    MOUNTING RECOMMENDATIONS Before mounting your Casablanca fan, read the following helpful recommendations. The location of the fan, air circulation, and fan size are all important factors to consider before installation. Location Ceiling fans have practical uses in almost every room in your home. We suggest you follow these mount- ing recommendations as you decide where to install your Casablanca fan.
  • Page 3: Preparation Instructions

    TOPIAN PREPARATION INSTRUCTIONS Unpacking: Before assembling and installing your ceiling fan, remove all parts from the shipping cartons and check them against the parts listed here. Before discarding packaging material, be certain that all parts have been removed. PERMA • LOCK™ HARDWARE ALLEN SET SCREW DOWNROD &...
  • Page 4: Fan Installation

    TOPIAN CEILING HARDWARE ADDITIONAL HARDWARE x 8-32 ROUNDED HEAD SCREW (2) CROSSBAR WIRE NUT (4) 1 x 8-32 ROUNDED MOUNTING FLAT WASHER (2) HEAD SCREW (2) BRACKET GETTING STARTED Installing a New Ceiling Fixture Outlet Box Using Existing Ceiling Fixture Outlet Box If you do not have an existing fixture located where you wish After turning the power OFF at its source (either circuit breaker to place your Casablanca fan, an approved ceiling fixture...
  • Page 5: Canopy Installation

    TOPIAN CANOPY INSTALLATION Step 2. Thread the wires from the ceiling through the opening in the canopy. Attach the canopy to CROSSBAR MOUNTING the crossbar mounting bracket with three of the BRACKET INSTALLED 8-32 x 2 long canopy screws and canopy lock washers.
  • Page 6: Canopy Hatch Installation

    TOPIAN CANOPY HATCH INSTALLATION Step 5. Tuck the wires into the canopy with the wire nuts pointed upwards, so that the WHITE and BLACK wires are on opposite sides of the canopy and all wires CANOPY are clear of the canopy opening. HATCH Step 6.
  • Page 7: Blade Installation

    TOPIAN BLADE INSTALLATION Step 9. Attach each blade to a blade holder securing it with the four blade screws provided. Using the screwdriver, tighten securely by hand only. BLADE BLADE SCREW (4 PER BLADE) BLADE HOLDER REMOVE SHIPPING BLOCKS Step 10. On the motor remove the five SHIPPING shipping blocks by unscrewing the screws.
  • Page 8: Remove Switch Housing Cap Screws

    TOPIAN REMOVE SWITCH HOUSING CAP SCREWS Step 12. Remove the two screws of the switch housing cap. Set the cap and screws aside for use in Step 15. INSTALL SWITCH HOUSING Step 13. Install 2 of the 3 switch housing screws onto the fan adapter plate, leaving ⁄...
  • Page 9: 3-Speed Operation

    3-SPEED OPERATION Pull-chain switches on the fan control the fan and lights. FAN & SPEED Using the fan control pull-chain switch: Fan off at start. REVERSE CONTROL First pull: fan ON, low speed PULL CHAIN PULL CHAIN SWITCH Second pull: medium speed Third pull: high speed Fourth pull: fan OFF Using the optional light pull-chain switch: Light off at start.
  • Page 10 Product SPecificationS ® ™ Model name: Utopian Motor: 172mm x 20mm Direct Drive Model number: 77xxD Blade Span With: 50" Blade Pitch: 16° dimensions: A = 10.7" no. of Blades: B = 12.22" technology: 3-Speed 3" D = 11.2" Airflow: 6,152 cfm 5.6"...