Vacuum tool
Microprocessor
Socket
Figure 55. Installing the microprocessor
a. Squeeze and hold the bladder of the vacuum tool; then, place the suction
cup on the microprocessor and release the bladder (see Figure 55).
Note: To maintain the correct orientation between the microprocessor and
the microprocessor socket during installation, observe the following
information:
v The microprocessor has two notches that are keyed to two tabs on the
sides of the socket.
v A triangle-shaped indicator on one corner of the microprocessor points
to a 45-degree angle on one corner of the socket.
b. Using the vacuum tool, carefully place the microprocessor into the socket.
c. Squeeze the bladder of the vacuum tool to release the microprocessor
from the suction cup.
3. Close the microprocessor bracket frame; then, close the microprocessor
retention latch and lock it securely in place (see Figure 56).
Figure 56. Microprocessor bracket frame
4. Install the fan sink.
a. Make sure that the fan-sink retention lever is in the fully open position.
Chapter 4. Removing and replacing computer components