Boot block
jumper (J22)
Figure 63. Recovery jumper locations
10. Turn on the computer and the monitor.
11. Disconnect all power cords; then, remove the computer cover.
12. Remove any adapters that impede access to the jumper; then, return the BIOS
13. Replace any adapters that you removed; then, replace the cover.
14. Reconnect all external cables and power cords.
15. Turn on the attached devices and turn on the computer to restart the operating

Interrupt status port register error procedures

Use interrupt status port register (ISPR) error procedures to help you solve
ServeRAID problems. A complete list of error codes is listed in "ServeRAID error
codes" on page 142.
EF10 (Default ISPR)
1. There is no ISPR error.
140
IBM IntelliStation Z Pro Type 9228 and 9232: Problem Determination and Service Guide
BUS width jumper (J11)
6. Move the BIOS recovery jumper to pins 2 and 3.
7. Replace any adapters that were removed; then, replace the side cover.
8. Connect the computer to a power source, keyboard, monitor, and mouse.
9. Insert the update CD into the CD or DVD drive.
Note: After the update session is completed, remove the CD from the drive
and turn off the computer. After the BIOS recovery is complete, the computer
will power down.
recovery jumper to pins 1 and 2.
system.
Clear CMOS jumper (J9)
BUS width jumper (J10)
BIOS recovery
jumper (J80)