Parallel Port; Viewing Or Changing The Parallel-Port Assignments - IBM 86655RY - Netfinity 7600 - 8665 Hardware Maintenance Manual

Models 1ry, 2ry
Table of Contents

Advertisement

Serial A
System management
Serial B
ASM Interconnect
port A
ASM Interconnect
port B

Parallel port

The server has one parallel port. This port supports three standard Institute of
Electrical and Electronics Engineers (IEEE) 1284 modes of operation: Standard Parallel
Port (SPP), Enhanced Parallel Port (EPP), and Extended Capability Port (ECP).
Viewing or changing the parallel-port
assignments
You can use the built-in Configuration/Setup Utility program to configure the
parallel port as bidirectional; that is, so that data can be both read from and written to
a device. In bidirectional mode, the server supports the ECP and EPP modes.
To view or change the parallel-port assignment:
1.
2.
3.
4.
5.
82
Hardware Maintenance Manual: Netfinity 7600 – Type 8665 Models 1RY, 2RY
Advanced Systems
Management Interconnect knockout
Keyboard
Ultra2 SCSI
Restart the server and watch the monitor screen.
When the message
Note: The Devices and I/O Ports choice appears only on the full configuration
menu. If you set two levels of passwords, you must enter the
administrator password to access the full configuration menu.
From the main menu, select Devices and I/O Ports; then, press Enter.
Select the parallel port; then, use the arrow keys to advance through the settings
available.
Note: When you configure the parallel port as bidirectional, use an IEEE 1284-
compliant cable. The maximum length of the cable must not exceed 3
meters (9.8 feet).
Select Save Settings; then, select Exit Setup to exit from the Configuration/Setup
Utility main menu.
Mouse
Parallel
Ethernet
USB1
USB2
Video
appears, press F1.

Advertisement

Table of Contents
loading

This manual is also suitable for:

866561y - eserver xseries 250Netfinity 7600 8665

Table of Contents