Error Code/Symptom
1800
(No more hardware interrupt
available for PCI adapter)
(Drive does not contain a valid
1962
boot sector)
2400
(Video controller test failure)
2462
(Video memory configuration
error)
5962
(IDE CD-ROM configuration
error)
8603
(Pointing Device Error)
00012000
(Machine check architecture
error)
00019501 (Processor 1 is not functioning -
check VRM and processor LEDs)
00019502 (Processor 2 is not functioning -
check VRM and processor LEDs)
00019503 (Processor 3 is not functioning -
check VRM and processor LEDs)
230
Hardware Maintenance Manual: Netfinity 7600 – Type 8665 Models 1RY, 2RY
1.
Run Configuration/Setup
2.
Failing Adapter
3.
I/O Legacy Board
1.
Verify a bootable operating system is installed.
2.
If RAID system, refer to the IBM ServeRAID Hardware Maintenance
Manual for more information.
3.
Run Diagnostics
4.
Hard Disk Drive
5.
Cable
6.
SCSI Backplane
7.
I/O Legacy Board
1.
Video Adapter (if installed)
2.
I/O Legacy Board
1.
Video Adapter (if installed)
2.
I/O Legacy Board
1.
Run Configuration/Setup
2.
CD-ROM Drive
3.
CD-ROM Power Cable
4.
IDE Cable
5.
I/O Legacy Board
6.
Battery
1.
Pointing Device
2.
I/O Legacy Board
1.
Processor
2.
Optional Processor
3.
Processor/PCI Board
1.
VRM 1
2.
Processor 1
3.
Processor Board
4.
I/O Legacy Board
1.
VRM 2
2.
Processor 2
3.
Processor Board
4.
I/O Legacy Board
1.
VRM 3
2.
Processor 3
3.
Processor Board
4.
I/O Legacy Board
FRU/Action