10. After finishing configuring the system for network access, the installation
11. The installation is now complete. Shut down and restart the system for the
104
Hardware Maintenance Manual: Netfinity 7600 – Type 8665 Models 1RY, 2RY
user is attempting to use the Remote Workstation Control or Screen View
service and asking whether you want to permit this user to use this
service on your system. You can click Yes or No. If you do not make a
selection within 15 seconds (for example, if you are not sitting at your
system when the access attempt is made), Netfinity Manager will
automatically prevent the remote user from using the service on your
system.
Disable DNS Name Resolution
If the Disable DNS Name Resolution option is enabled, Netfinity
Manager will use only a numeric TCP/IP address (for example,
8.24.67.32) to communicate with remote systems and will not attempt to
resolve the numeric address into an alphanumeric, Domain Name Server
(DNS) address (for example, your.system.ibm.com). Select this option if
you are using Netfinity Manager is a WINS networking environment or if
you are using TCP/IP in an environment that does not have a Domain
Name Server.
To implement one or more of the available Netfinity Manager Options:
1) Click Options....
2) Select the Netfinity Manager options to be enabled.
3) Click Save.
f.
Set the Network Timeout Value (optional).
The Network Timeout field shows the number of seconds that Netfinity
Manager will attempt to communicate with a remote system that is not
responding. If Netfinity Manager does not establish contact with the remote
system within this time, it cancels the communication attempt. The Network
Timeout default setting is 15 seconds. This default setting might not need to
be altered.
g. Save the configuration and continue.
Click Save to save the configuration. Then, click Exit to continue.
Note: The configuration can be changed later by double-clicking the
Network Driver Configuration object in the Netfinity Manager folder.
program displays a list of changes that must be made to the system configuration
files, and asks whether the installation program should make the changes. For
example, if Netfinity Manager for Windows 95 is being installed, the installation
program will display a list of changes that must be made to the CONFIG.SYS file.
Click either Yes or No.
Note: These changes must be made to the system configuration for Netfinity
Manager to run correctly.
If you click Yes the changes are automatically made to the system
configuration.
If you click No the commands are saved to a file named CONFIG.NEW in the
destination directory (and to AUTOEXEC.NEW, if appropriate) so that they
can be added later.
system configuration changes to take effect.