Horizontal Alignment Offset (Stx O); Set Continuous Label Length (Stx P) - Brady TLS PC Link Programmer's Manual

Hide thumbs Also See for TLS PC Link:
Table of Contents

Advertisement

Horizontal Alignment Offset (STX o)

This command sets the point where printing starts relative to the left edge of the
label. This is an offset value from the default position.
<STX>osnn
Where:
s-
nn-
The valid range is -05 to +99.
Feedback possibilities: 0,1,2

Set Continuous Label Length (STX P)

This command will set the label length for continuous material. The label length
can be set from 0.00 inches to 6.00 inches (0.0mm to 152.4mm). This command
is useful for terminal block labels. It can be used with <STX>S to generate the
correct spacing between the terminals. If the length is set to zero, the printer will
be in banner mode. In banner mode, the label length is determined by the
amount of data on the label. The printer will print until there is no more data up
to 6 inches.
<STX>Pnnnn
Where:
nnnn-
Sample:
<STX>L
190000900000000TEST1<CR>
190000901000000TEST2<CR>
X<CR>
<STX>P0100
<STX>G
<STX>P0000
<STX>G
20
sign of offset, '+' or '-'
two digit value of offset
a four-digit label length in in/100 or mm/10