Service Interval Timer
Instructions on how to access this feature are available from our
customer support desk. Please note these are only issued to boni-fi de
heating installers.

Entering Installer Advanced Programming Mode

To access the Installer Advanced Programming
Mode follow the steps below:
a) Press and hold
enter User Advanced Programming, the display
will change to fi gure opposite.
b) Press and hold
to enter Installer Advanced Programming, the
display will change to fi gure opposite.
c) Use + and - keys to scroll backwards and forwards between options
V
Λ
then
and
on the right hand of the display indicates the number of the selected
option. The large characters display the option value selected.
d) To return to RUN, press and hold PROG until the display returns to
previous RUN mde.
Option 30 - Set upper limit of temperature range
This allows the upper limit of the thermostat setting
range to be electronically limited. Press + until
Option 30 is displayed, use V and Λ to select required
setting.
Setting
Option 31 - Set lower limit of temperature range
This allows the lower limit of the thermostat setting
range to be electronically limited. Press + until
Option 31 is displayed, use V and Λ to select required
setting.
Setting
5 - 40°C (Factory setting is 5°C)
V
and PROG for 3 seconds to
V
Λ
,
and PROG for 5 seconds
keys to change the option settings. The fl ashing digit
40 - 5°C (Factory setting is 30°C)