Danfoss TP5000 si range Installation And User Instructions Manual page 4

Electronic 5/2 day programmable room thermostat mains, battery and rf versions
Hide thumbs Also See for TP5000 si range:
Table of Contents

Advertisement

Installation
GB
First, remove the wallplate from the back of the unit.
From the top left hand corner of the wallplate, there must be
clearances of at least 15mm to the right, 15mm to the left, 30mm
above and 100mm below in order to mount the plug-in module.
Thermostat and Remote Room Sensor:
Fix at a height of approximately 1.5m from the fl oor, away from
draughts or heat sources such as radiators, open fi res or direct
sunlight.
Prior to mounting the unit the 2 DIL switches on the rear of the
unit have to be moved to the required position. The factory
presets are shown below.
Sw. No.
1
2
4
OFF
Keyboard disabled
Reset disabled
ON
Keyboard enabled
Reset enabled