Rx Receiver Wiring; Commissioning - Danfoss TP5000 si range Installation And User Instructions Manual

Electronic 5/2 day programmable room thermostat mains, battery and rf versions
Hide thumbs Also See for TP5000 si range:
Table of Contents

Advertisement

RX Receiver Wiring (RF models only)
RX1
ELECTRONICS
N L
1 2 3 4
1) For mains voltage operated systems link terminal 2 to mains live supply.
2) Power supply to unit must not be switched by timeswitch.
I M P O R T A N T
To ensure that the factory programmes are set and the micro-
computer is operating correctly it is essential that you press and
hold the RESET button before you begin any commissioning or
programming.
Commissioning (RF models only)
If the thermostat and the receiver have been supplied together in
a combined pack, the units have been paired in the factory and no
commissioning is required (RX1 only).
To make the RX receiver learn the thermostat's signal, follow steps 1-5
below.
Step 1
TP5000-RF Si - Reset the unit by pressing the recessed reset button.
Step 2
Press and hold V and + buttons for 3 seconds
(TP5000 RF Si now transmits unique signal
continuously for 3 minutes).
COM
ZONE
ZONE
1 OFF
1 ON
RX2 & RX3
ELECTRONICS
A
B C 1 2 3 4 5 6
L
N
COM
TERMINAL 6
RX3 ONLY
ZONE
ZONE
ZONE
ZONE
1 ON
1 OFF
2 ON
3 ON
GB
7