Grounding instructions (e ectr c
ignition models only)
IMPORTANT:
READ AND SAVE THESE INSTRUCTIONS.
This appliance is equipped with a 3-prong grounding plug for
your protection against shock hazard and should be plugged directly into a
properly grounded receptacle. DO NOT cut or remove the grounding prong
from this plug.
For personal safety, this oven must be properly grounded.
For maximum
safety, the power cord must be plugged into a 120V--60
Hz. outlet that is
correctly polarized and properly grounded.
If a two-prong wall receptacle is the only available outlet, it is the personal
responsibility of the consumer to have it replaced with a properly grounded
three-prong wall receptacle installed by a qualified electrician.
Do not under any circumstances cut or remove the third round grounding
prong from the power cord plug. See the installation instructions packaged
with this oven for complete installation and grounding instructions. Do not
operate the oven using a two-prong adapter or an extension cord.
Avoid
fire
hazard
or
electrical shock. Do not use an adaptor
plug,
an extension
cord,
or remove
grounding prong from electrical power cord.
Failure to follow this warning can cause
serious injury, fire or death.
Grounding
type wall
receptacle
-x
Do not, under any
circumstances,
cut, I
remove, or bypass|
the grounding pron_)
Power supply cord with
3-prong grounding plug
Oven ignition
When you turn the oven on, the glow bar igniter begins to heat. When the lighter is hot enough, in less than 1 minute, the gas _i
flows into the burner and is ignited.
The igniter glows bright orange when hot. It cycles on and off with the thermostat and will glow whenever the burner is on.
Do not attempt to light the oven burners during a power failure. The oven burner valves will not open up
and will prevent the gas from flowing through the burner valves to the burners. In the event of a power failure, turn the
Temperature Control knob to OFF. When power resumes, turn the Temperature Control knob back to desired temperature.
Conversion
to Liquefied Petroleum Gas (or L. P. Gas)
This natural gas range is designed to allow for conversion to Liquefied Petroleum (L. P.) Gas.
Only a qualified service agent should perform the L. P. conversion. Contact the local gas provider for conversion. An L. P.
Conversion Kit is supplied with this range and is located on the main back of the range. The kit contains installation instructions
which must be read before and followed carefully when installing the kit.
To avoid serious injury, any additions, changes or conversions
required in order for this appliance to
satisfactorily meet the application needs must be made by a qualified service agent.