low suction or poor pickup may be
due to a clog in the vacuum. if you
notice a change in the sound of the
vacuum motor, check for clogs.
1. Turn power OFF. Unplug the vacuum
from electrical outlet.
2. Remove the Bag Tank from the vacuum
cleaner by sliding the Lock 'n Seal lever
from right to left into the "Unlock"
position. Check the upper tank for
debris build-up or clogs.
3. To check the suction inlet for a clog,
remove the Dirt Path Ramp by twisting
clockwise and pulling the ramp straight
down out of the upper tank. The suction
inlet is located in the upper right corner
of the upper tank.
4. Grasp the Quick Reach Handle and
lift up to separate the Hose Wand from
the Hose Wand Base to check for clogs
in the base, the wand, and the hose.
5. Remove the screw attaching the Hose
Wand Base to the vacuum. Straighten
the Hose Wand Base and unclog
with a long, narrow object such as
a broomstick.
6. If the clog persists, follow the
instructions for checking the rotating
floor brush on page 10 and inspect
the air passageway for obstuctions.