Alto-Shaam CT EXPRESS 4•10ESi Installation Manual
Alto-Shaam CT EXPRESS 4•10ESi Installation Manual

Alto-Shaam CT EXPRESS 4•10ESi Installation Manual

Combination oven / steamer
Hide thumbs Also See for CT EXPRESS 4•10ESi:

Advertisement

Shown with ExpressTouch control
and optional hand sprayer
W164 N9221 Water Street • P.O. Box 450 • Menomonee Falls, Wisconsin 53052-0450 USA
PHONE:
262.251.3800 • 800.558.8744
.
.
.
p r i n t e d i n u
s
a
Oven / Steamer
/
usa
caNada
.
-
.
www
altO
sHaaM
cOM
C o m b i t h e r m
C o m b i n a t i o n
CT ExprESS™
4•10esi
4•10esiVH
• InstallatIon
FaX:
262.251.7067 • 800.329.8744
®
.
.
.
u
s
a
ONly
M N - 2 9 8 0 5 • 0 8 / 1 2

Advertisement

Table of Contents
loading

Summary of Contents for Alto-Shaam CT EXPRESS 4•10ESi

  • Page 1 C o m b i t h e r m ® C o m b i n a t i o n Oven / Steamer CT ExprESS™ 4•10esi 4•10esiVH Shown with ExpressTouch control and optional hand sprayer • InstallatIon W164 N9221 Water Street • P.O. Box 450 • Menomonee Falls, Wisconsin 53052-0450 USA PHONE: 262.251.3800 •...
  • Page 2: Table Of Contents

    Delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Wire Diagrams Always refer to the wire diagram(s) included with the unit Unpacking .
  • Page 3: Delivery

    Tech Team service manuals are available from the alto-shaam department if you have any questions concerning tech team service department.
  • Page 4: Safety Procedures And Precautions

    safety procedures and precautions Knowledge of proper procedures is essential to the 1. This appliance is intended to cook, hold safe operation of electrically and/or gas energized or process foods for the purpose of human equipment. in accordance with generally accepted consumption.
  • Page 5: Installation

    i n s t a l l a t i o n s i t e i n s t a l l a t i o n d a n g e r d a n g e r IMPROPER INSTALLATION, AVERTISSEMENT : UNE INSTALLATION, ALTERATION, ADJUSTMENT,...
  • Page 6: Positioning On Site

    i n s t a l l a t i o n s i t e i n s t a l l a t i o n c a u t i o n ® THE APPLIANCE MUST REMAIN ON THE PALLET WHILE BEING MOVED TO THE INSTALLATION SITE BY FORK LIFT OR PALLET LIFT TRUCK.
  • Page 7: Lifting Instructions

    i n s t a l l a t i o n l i f t i n g i n s t r u c t i o n s remove banding before lifting. lift the unit from either side of the unit, never from the front or back...
  • Page 8: Stand Installation

    i n s t a l l a t i o n s i t e i n s t a l l a t i o n positioning requirements 4" (102mm) q in order to ensure proper ventilation, a minimum distance of at least 4-inches (101mm) must be kept from 18"...
  • Page 9: Accessories

    i n s t a l l a t i o n a c c e s s o r i e s combiclean® Tablets — ce-28892 sPEcially FOrMulatEd FOr cOMbitHErM OvENs , 90 ➥ cONtaiNErs PackEts EacH cONtaiNEr combitherm cleaning liquid — ce-24750 sPEcially FOrMulatEd FOr cOMbitHErM OvENs (12)
  • Page 10: Specifications, 4•10Esi

    33-1/2" x 23-7/16" x 35-3/4" (850mm x 593mm x 906mm) water requirements water quality minimum standards ONE (1) COLD WATER INLETS - DRINKING QUALITY using a waTer supply noT MeeTing alTo-shaaM’s MiniMuM waTer QualiTy sTandards will Void This warranTy. ONE (1) WATER INLET: 3/4" g*...
  • Page 11: Specifications, 4•10Esivh

    45-1/2" x 23-3/4" x 37-13/16" (1156mm x 603mm x 960mm) water requirements water quality minimum standards ONE (1) COLD WATER INLETS - DRINKING QUALITY using a waTer supply noT MeeTing alTo-shaaM’s MiniMuM waTer QualiTy sTandards will Void This warranTy. 3/4" g* ONE (1) WATER INLET:...
  • Page 12: Electrical Connection

    i n s t a l l a t i o n e l e c t r i c a l c o n n e c t i o n d a n g e r d a n g e r ENSURE POWER SOURCE To avoid electrical shock, this appliance MUST be adequately...
  • Page 13 i n s t a l l a t i o n e l e c t r i c a l c o n n e c t i o n note: where local codes and ce regulatory d a n g e r requirements apply, appliances must be connected to an electrical circuit that is protected by an external gFci outlet.
  • Page 14: Mobile Equipment Restraint

    i n s t a l l a t i o n m o B i l e e q u i p m e n t r e s t r a i n t any appliance that is not furnished with a a mounting connector for a restraining device is power supply cord but includes a set of casters, located on the top right back panel of the appliance...
  • Page 15: Water Quality Requirement

    equipment.
  • Page 16: Water Connections

    Figure 1 above For to treated connection treatment system on oven ProPer intaKe locations. alto-shaam now offers an improved water filtration system for combitherm . The combiguard™ triple-guard water filtration ® system filters dirt, sediment, and other debris as small as 1/2 micron.
  • Page 17: Hand Held Spray Hose

    i n s t a l l a t i o n o p t i o n a l h a n d h e l d s p r a y h o s e Sprayer hanger Sprayer hose Valve Valve bracket i ns t a lla t io n...
  • Page 18: Water Drainage

    i n s t a l l a t i o n w a t e r v a l v e note: the shut-oFF valve must be in the oPen Position when the oven is being used. w a t e r d r a i n a g e The oven must discharge through an indirect waste pipe by means of an air gap.
  • Page 19: Ventless Hood Information

    The Ventless hood option is factory installed directly on the top of the alto-shaam combitherm oven. The hood is designed to vent clean air back into the kitchen, filtering vapors and grease.
  • Page 20: Ventless Hood Filters

    i n s t a l l a t i o n v e n t l e s s h o o d m o d e l t o p e x ha us t v ent f i l t e r t ra c k f i l t e r s w i t ch 1 Charcoal Filter: The charcoal filter should be 2 Grease Filter: cleaning frequency should be...
  • Page 21: Installation Checklist

    Verify 1/8" (3.2mm) pitch to 10' (305cm) of drain line. on This uniT? iMporTanT: Alto-Shaam has listed Water Quality Requirements in the sTore has seen This installation manual for this equipment. It is the responsibility of the end...
  • Page 22: Error Codes

    ☛ check that unit is receiving power. circuit breaker turned on? do not attempt to repair or service the oven beyond this point. contact alto-shaam for the nearest authorized service agent. repairs made by any other service agents without prior authorization by alto-shaam will void the warranty on the unit.
  • Page 23 control error codes error codes error error call out in display description of error possible cause code Boiler Temperature High Boiler temperature overheats — Scale build up inside steam generator . — Scale build up on water level probe . —...
  • Page 24 error codes control error codes error error call out in display description of error possible cause code Steam Generator Drain Water level in steam — Scale build up inside the steam generator pump Fault generator does not drop drain pump . during cleaning program —...
  • Page 25 control error codes error codes error error call out in display description of error possible cause code No Rinse Water During rinse no water — Water supply is shut off. — Low water pressure . flow is detected through — Check wiring to all components mentioned below. solenoid valve —...
  • Page 26 error codes when the oven malfunctions, an error code will appear in the display. PRESS THE START ICON TO ACKNOWLEDGE THE ERROR. The icons that begin to flash represent operational modes that are still usable. when the oven fault is corrected, the combitherm will return to normal operation. model mode error...
  • Page 27: Original Equipment Limited Warranty

    PRODUCT, OR FOR ANY INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES. No person except an officer of Alto-Shaam, Inc. is authorized to modify this warranty or to incur on behalf of Alto-Shaam any other obligation or liability in connection with Alto-Shaam equipment.
  • Page 28: Transportation Damage And Claims

    F.o.B. shipping point, and when accepted by the carrier, such shipments become the property of the consignee.