Alto-Shaam CT Express Installation Manual
Alto-Shaam CT Express Installation Manual

Alto-Shaam CT Express Installation Manual

Combination oven/steamer

Advertisement

Quick Links

WARNING
To prevent personal injury, death or
property damage:
Do not store or use gasoline or other
flammable vapors or liquids in the vicinity
of this or any other appliance.
W164 N9221 Water Street • P.O. Box 450
Menomonee Falls, Wisconsin 53052-0450 U.S.A.
PHONE: 262.251.3800 • 800.558.8744 U.S.A. / CANADA
FAX: 262.251.7067 • 800.329.8744 U.S.A. ONLY
www.alto-shaam.com
Printed in the U.S.A.
Combination Oven/Steamer
Shown with ExpressTouch Control
Combitherm®
CT Express™
CTX4-10E
CTX4-10EVH
CTX4-10EC
• Installation
WARNING
Improper installation, alteration, adjustment, service,
cleaning, or maintenance could result in property
damage, severe injury, or death.
Read and understand the installation, operating and
maintenance instructions thoroughly before installing,
servicing, or operating this equipment.
Consult instructions
for operation and use.
MN-29805 • Rev. 10 • 06/17

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CT Express and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Alto-Shaam CT Express

  • Page 1 Combitherm® Combination Oven/Steamer CT Express™ CTX4-10E CTX4-10EVH CTX4-10EC • Installation Shown with ExpressTouch Control WARNING WARNING Improper installation, alteration, adjustment, service, cleaning, or maintenance could result in property damage, severe injury, or death. To prevent personal injury, death or property damage:...
  • Page 2: Table Of Contents

    Table of Contents Delivery Transportation Damage and Claims Unpacking Safety Procedures Installation Dimensions Electrical Connection Water Inlet Connection Water Drain Connection Operation Cleaning and Preventative Maintenance Service Limited Warranty MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...
  • Page 3: Delivery

    • Ambient temperature range of 60°F to 110°F (16°C to 43°C) leveling appliance and handling accessories. • Relative humidity of less than 95% non‑condensation • Atmospheric pressure range of 50kPa to 106kPa MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...
  • Page 4: Transportation Damage And Claims

    United States through the use of Alto-Shaam’s toll-free ______________________________________________ number. Emergency service access is available seven ______________________________________________ days a week including holidays. MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...
  • Page 5: Unpacking

    • Remove all protective plastic fi lm, packaging materials, and accessories from the appliance before connecting electrical power Store any accessories in a convenient place for future use MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...
  • Page 6: Safety Procedures

    2012/95/EC WEEE personal injury. Do not dispose of electrical or electronic equipment with other municipal waste. Indicates that referral to operating instructions is recommended to understand operation of equipment. MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...
  • Page 7 • Always open the appliance door very slowly Escaping hot vapors or steam can cause serious injury or death MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...
  • Page 8: Installation

    IN ACCORDANCE WITH NFPA 54 COMMONWEALTH OF MASSACHUSETTS ONLY. MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...
  • Page 9: Positioning On Site

    Do not store or use gasoline or other damage electrical and electronic components flammable vapors or liquids in the vicinity of this or any other appliance. MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...
  • Page 10: Lifting Instructions

    Appliance and accessories may be heavy. To prevent serious injury, always use a su icient number of trained and experienced workers when moving or leveling appliance and handling accessories. MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...
  • Page 11: Positioning Requirements

    22-1/4" (565mm) 22-1/4" (565mm) SHOWN ON 18-3/8" CASTER STAND SHOWN ON 18-3/8" CASTER STAND 4) Secure the CT Express to the stand in four places with UNIT REQUIRES TETHER BRACKET UNIT REQUIRES TETHER BRACKET screws and Lock Washers SHOWN ON 18-3/8" CASTER STAND SHOWN ON 18-3/8"...
  • Page 12 Wood Chips — bulk pack 20 lb (9 kg) ☐ Apple WC‑22543 ☐ Cherry WC‑22541 ☐ Hickory WC‑2829 ☐ Maple WC‑22545 Fry Basket BS-26730 Grilling Grate SH-26731 Scale Free ™ CE-27889 MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...
  • Page 13 Complete and submit warranty registration documentation: www.alto-shaam.com/warranty Use the appliance only for its intended purpose. Follow cleaning and planned maintenance schedules to maximize the life of the equipment. MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...
  • Page 14 Customer/End User Complete and submit warranty registration documentation. Use the appliance only for its intended purpose. Follow cleaning and planned maintenance schedules to maximize the life of the equipment. MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...
  • Page 15 Is water treatment (RO blend system, filter, etc.) being used? If YES - Note the system here: Can the site contact provide evidence that a documented water analysis has been performed? MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...
  • Page 16 1.5" (38mm) change in elevation from its highest to lowest surface point? Is the site 100% ready for appliance(s) installation? Is site action required? Action Required: Comments: MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...
  • Page 17 Are all interior water connections tight prior to operation? Are there any exterior water leaks a er operation? Are there any interior water leaks a er operation? Comments: MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...
  • Page 18 Other Site Information Is there a proper ventilation hood installed above the location of the appliance(s)? Is the appliance level according to leveling instructions in the installation manual? Comments: MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...
  • Page 19 Check motor rotation for CTC models. Note: Arrows on the motor housing indicate proper rotation. Check all lines and connections for leaks, both inside and outside of the combi appliance. MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...
  • Page 20 Picture of gas line and connections at combi appliance Picture of appliance in place with surrounding equipment Are water supply lines 3/4" inside diameter? Size of treated water line: Size of untreated water line: MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...
  • Page 21: Electrical Connections

    Verify the appliance is level and installed on a solid, water resistant surface Service Agency: Start‑Up Date: Installation Name: Model No : Serial No : Tech Signature: Customer Signature: MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...
  • Page 22 This page intentionally left blank. MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...
  • Page 23: Mobile Equipment Restraint

    A single wall anchor may be used. severe personal injury. Mounting connector for restraining device REAR VIEW MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...
  • Page 24 3 supplied screws. 3. Connect the sprayer hose to the valve and place the sprayer in the hanger. 4. Continue to connect an incoming water supply line to the valve. MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...
  • Page 25: Dimensions

    **ON WIRE SHELVES ONLY. ADDITIONAL WIRE SHELVES REQUIRED FOR MAXIMUM CAPACITY DOMESTIC GROUND SHIPPING INFORMATION CONTACT FACTORY † CAPACITY WITHOUT BROILER ELEMENT OPTION FOR EXPORT WEIGHT AND DIMENSIONS MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...
  • Page 26 VOLUME MAXIMUM 30 quarts (38 liters) DOMESTIC GROUND SHIPPING INFORMATION CONTACT FACTORY FOR ON WIRE SHELVES ONLY ADDITIONAL WIRE SHELVES REQUIRED FOR MAXIMUM CAPACITY EXPORT WEIGHT AND DIMENSIONS MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...
  • Page 27 DOMESTIC GROUND SHIPPING INFORMATION CONTACT FACTORY FOR ON WIRE SHELVES ONLY ADDITIONAL WIRE SHELVES REQUIRED FOR MAXIMUM CAPACITY † EXPORT WEIGHT AND DIMENSIONS CAPACITY WITHOUT BROILER ELEMENT OPTION MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...
  • Page 28: Electrical Connection

    15 minutes and recheck the main power connections at the terminal block to make certain they remain tight. MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...
  • Page 29 Top/Back of Appliance EQUIPOTENTIAL GROUND SCREW INCOMING ELECTRICAL TERMINALS 220-240V, 1PH & 380-415V APPLIES TO 208-240V & 380-415V UNITS CUSTOMER MUST SUPPLY CORD INTERNAL GROUND STUD GROUND MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...
  • Page 30 Power supply side 1 PH Chassis 3 PH Chassis 1/2” (12mm) *Also referred BK RD OR WH* BK RD OR WH* to as neutral. MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...
  • Page 31 1/2" (12mm) *Also referred BK WH* to as neutral 3 PH Chassis 1/2" (12mm) BK RD OR GR MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...
  • Page 32: Water Inlet Connection

    To prevent water pipes from bursting, is activated. incoming water supply should be turned Verify water supply before starting cleaning program. off when the appliance is not in use. MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...
  • Page 33 (CORD OR HARDWIRE) INLET 3/4" G Install water intake filter UNTREATED WATER INLET 3/4" G HAND SPRAYER VALVE REQUIRES SEPARATE 3/4" GHT CONNECTION 1-1/2" (40mm) DRAIN TANK CLEAN-OUT MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...
  • Page 34: Water Drain Connection

    REAR VIEW WASTE PIPE 2" (51mm) Minimum NPT diameter Manifold Pipe materials must withstand 200°F (93°C) temperatures up to 1-1/2" (40mm) TOLERANCE: UNLESS SPECIFIED: diameter connection required for drain MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...
  • Page 35: Operation

    The closed properly. latch is located on the right side of the appliance, toward the back. MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...
  • Page 36 Rinse thoroughly. Allow the fi lter to air dry before reinstalling. FI-24114 To replace the grease fi lter, the metal handles on the fi lter casing should be facing toward the front of the appliance. FI-24113 MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...
  • Page 37: Cleaning And Preventative Maintenance

    Component Failure & Replacement List details of the failure(s) next to the day they occurred. Leave blank if components are working properly. Monday Tuesday Wednesday Thursday Friday Saturday Sunday MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...
  • Page 38 Component Failure & Replacement List details of the failure(s) next to the day they occurred. Leave blank if components are working properly. Week 1 Week 2 Week 3 Week 4 MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...
  • Page 39 Test ventless hood drain for proper drainage and signs of leaking Employee initials EB Electric boiler units only Component Failure & Replacement Summarize any component failure(s) that may have occurred during this month. MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...
  • Page 40 Inspect - Behind the fan panel inside the oven cavity for signs of grease/carbon buildup Inspect - Behind the fan panel inside the oven cavity for signs of scale buildup EB Electric boiler units only G Gas units only Electric units only MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...
  • Page 41 Inspect & Tighten - All electrical connections Inspect & Tighten - All cooling fans for proper operation EB Electric boiler units only G Gas units only Electric units only MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...
  • Page 42 Record - Amperage across all three legs (when heating) Function test all components (list components) Component Failure & Replacement Summarize any component failure(s) that may have occurred during this month. Customer Signature: ___________________________________________________ Technician Signature: ___________________________________________________ MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...
  • Page 43: Service

    Do not attempt to repair or service the appliance beyond this point. Contact Alto-Shaam for the nearest authorized service agent. Repairs made by any other service agents without prior authorization by Alto-Shaam will void the warranty.
  • Page 44: Error Codes

    N8 Immersion Element N8 probe “open” — Faulty N8 safety temperature probe connection at relay board. — Faulty N8 safety temperature probe. Safety Probe Fault Continued on next page MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...
  • Page 45 — Faulty connection at vent motor, vent motor switch or relay board. — Fault vent valve safety switch (micro switch). — Faulty vent motor. Continued on next page MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...
  • Page 46 — Faulty compact flash card. — Relay board, low voltage, connector defective. — Display board connector defective. — So ware may need to be updated again. Continued on next page MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...
  • Page 47 — Boiler drain pump motor not being energized. not running. — Boiler drain pump faulty. — Poor connection at pump motor and/or relay board. — Hall e ect sensor wiring/connection error/failure. MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...
  • Page 48: Error Codes

    Fan Motor 2 High Temperature Vent Not Open NO BROWNING NO BROWNING NO BROWNING NO BROWNING No Rinse Water Communication Error FROM Display Board Communication Error TO Display Board MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual...