Electrical requirements

For successful installation and operation of the switch, ensure that the following
electrical requirements are met.
v Primary ac input 100-240 V ac (the switch autosenses input voltage)
v Correctly wired primary outlet, with circuit protected by a circuit breaker and
v Adequate supply circuit, line fusing, and wire size, as specified by the electrical

Environmental requirements and considerations

To ensure proper operation, the switch must not be subjected to environmental
conditions beyond those for which it was tested. The ranges specified in Table 3 list
the acceptable environment for both operating and non-operating conditions.

Installing a stand-alone SAN16B-2

To install the switch as a stand-alone unit, use the following procedure:
1. Unpack the switch and verify that all items listed in "Items included with the
2. Clean the four corner depressions on the bottom of the switch enclosure, place
3. Place the switch on a flat, sturdy surface.
4. Provide power to the switch as described in "Powering up the switch and
Attention:
correctly set. For instructions on how to cable and configure the switch, and how to
set the IP address, see "Cabling and configuring the SAN16B-2" on page 16.
grounded in accordance with local electrical codes
rating on the switch nameplate
Table 3. Environmental requirements
Condition
Acceptable range during operation
Temperature
-10° to + 40° C (14° to 104° F)
Humidity
20% to 85% RH non-condensing, at 40°
C (104° F), with maximum gradient of
10% per hour
Altitude
0 to 3,000 m (9,800 ft) above sea level
Shock
20 G, 6 ms duration, half-sine wave
Vibration
0.5 G, 5–500 Hz
Air flow
40.1 cubic meters per hour (24 cubic feet
per minute)
switch" on page 7 are present and undamaged.
Note: If any items are damaged or missing, contact the IBM Quality Hotline
toll-free at 1-800-442-6773 within the United States and Canada, or
direct dial 770-858-8459 in other locations.
an adhesive rubber foot in each one, and firmly press into place. Applying the
rubber feet onto the switch helps prevent the switch from sliding off the
supporting surface.
logging in" on page 18.
Do not connect the switch to the network until the IP address is
Acceptable range during
non-operation
-50° to 100° C (-22° to 212° F)
10% to 85% RH
non-condensing, at 70° C (158°
F)
0 to 12 km (39,370 ft) above sea
level
15 G, 12–18 ms duration,
trapezoid
2.0 G, 5–500 Hz
None required
Chapter 2. Installing and configuring the SAN16B-2
9