Safety Compliance; Underwriters Laboratories Compliance Statement - Accton Technology SwitcHub-2s Installation Manual

2-port ethernet switching hub for 10base-t/100base-tx
Table of Contents

Advertisement

Safety Compliance

Operating Voltage
120 Volts
240 Volts (For North America)
240 Volts (For Europe only)
D-4
SwitcHub-2s User's Guide

Underwriters Laboratories Compliance Statement

Important! Before making connections, make sure you have the
correct Cord Set. Check it (read the label on the cable) against the
following specification list.
UL Listed/CSA Certified Cord Set
Minimum 18 AWG
Type SVT or SJT three conductor cord
Maximum length of 15 feet
Parallel blade, grounding type attachment plug rated 15A, 125V
UL Listed/CSA Certified Cord Set
Minimum 18 AWG
Type SVT or SJT three conductor cord
Maximum length of 15 feet
Tandem blade, grounding type attachment plug rated 15A, 125V
Cord Set with H05VV-F cord having three conductors with minimum diameter of 0.75 mm
IEC-320 receptacle
Male plug rated 6A, 250V
The unit automatically matches the the connected input voltage.
Therefore, no additional adjustments are necessary when connecting it
to any input voltage within the range marked on the rear panel.
Regulatory Standards Compliance
Cord Set Specifications
2