Fibre Channel Port Specifications; Post And Boot Specifications; Post; Laser Data Transmission Ranges For The 8/80 San Switch - HP StorageWorks 8/24 - SAN Switch Hardware Reference Manual

8gb san switch
Hide thumbs Also See for StorageWorks 8/24 - SAN Switch:
Table of Contents

Advertisement

Table 22 Laser data transmission ranges for the 8/80 SAN Switch
Port speed
1Gb/s
2Gb/s
4Gb/s
8Gb/s
Fibre Channel port specifications
The Fibre Channel ports in the 8Gb SAN Switch are compatible with SWL, LWL, and ELWL SFP
transceivers. The strength of the signal is determined by the type of transceiver in use.
The ports meet all required safety standards.
The ports are capable of operating at 1, 2, 4, or 8Gbps and are able to autonegotiate to the maximum
link speed.
POST and boot specifications
The switch performs POST by default each time it is powered on or rebooted or the system is reset. Boot
time with POST is usually about 1 to 3 minutes.
POST can be skipped after subsequent reboots by entering the fastBoot command. For more
information about this command, see theFabric OS command reference manual.

POST

The success/fail results of the diagnostic tests that run during POST can be monitored through LED
activity, the error log, or the CLI.
nl
POST:
Conducts preliminary POST diagnostics.
Initializes the operating system.
Initializes hardware.
68
Technical Specifications
Cable size
Short wavelength
(microns)
50
500 m (1,640 ft)
62.5
300 m (984 ft)
9
N/A
50
300 m (984 ft)
62.5
150 m (492 ft)
9
N/A
50
150m (492 ft)
62.5
70 m (230 ft)
9
NA
50
150 m (492 ft)
62.5
21 m
9
N/A
Long
Extended long
nl
wavelength
wavelength
10 km (6.2 miles)
N/A
10 km (6.2 miles)
N/A
10 km (6.2 miles)
80 km (50 miles)
N/A
N/A
10 km (6.2 miles)
N/A
10 km (6.2 miles)
without an HP Extended
Fabrics license
80 km (50 miles)
50 to 100 km with an
HP Extended Fabrics
license
NA
NA
NA
NA
10 km
NA
N/A
N/A
N/A
N/A
10 km (6.2 miles)
N/A