Storage Controller Installation Guidelines; Installing A Storage Controller - HP ProLiant DL388e User Manual

Hp proliant dl388e gen8 server user guide
Hide thumbs Also See for ProLiant DL388e:
Table of Contents

Advertisement

CAUTION:
pinout. Do not use the controller with cache modules designed for other controller models,
because the controller can malfunction and you can lose data. Also, do not transfer this cache
module to an unsupported controller model, because you can lose data.
CAUTION:
the capacitor pack while an array capacity expansion, RAID level migration, or stripe size
migration is in progress.
CAUTION:
before unplugging the cable from the cache module. If the amber LED flashes after 30 seconds,
do not remove the cable from the cache module. The cache module is backing up data. Data will
be lost if the cable is detached when the amber LED is still flashing.
IMPORTANT:
low charge a POST error message appears when the server is powered up, indicating that the
capacitor pack is temporarily disabled. No action is necessary. The internal circuitry
automatically recharges the capacitors and enables the capacitor pack. This process might take
up to 4 hours. During this time, the cache module functions properly but without the performance
advantage of the capacitor pack.

Storage controller installation guidelines

Install the storage controller option in slots 1–3 of the primary PCI riser cage.
Do not install a storage controller option in slot 4 of the primary PCI riser cage.
The secondary PCI riser cage option supports storage controller installation.
For more information on the riser board slot specifications, see "PCIe riser board slot definitions (on
page 11)."

Installing a storage controller

Power down the server (on page 18).
1.
Remove all power:
2.
Disconnect each power cord from the power source.
a.
Disconnect each power cord from the server.
b.
Do one of the following:
3.
Extend the server from the rack (on page 18).
o
Remove the server from the rack (on page 20).
o
Remove the access panel (on page 21).
4.
Install the storage controller
5.
Connect all necessary internal and external cabling to the storage controller.
6.
For more information on these cabling requirements, see the documentation that ships with the option.
For more information on internal cable routing in supported drive configurations, see "Storage cabling
(on page 82)."
Install the access panel (on page 21).
7.
The cache module connector does not use the industry-standard DDR3 mini-DIMM
To prevent a server malfunction or damage to the equipment, do not add or remove
After the server is powered down, wait for 30 seconds, and then check the amber LED
The capacitor pack might have a low charge when installed. If the pack does have
("Expansion board
option" on page 70).
Hardware options installation 47