CAUTION:
the battery pack while an array capacity expansion, RAID level migration, or stripe size migration
is in progress.
CAUTION:
before unplugging the cable from the cache module. If the amber LED flashes after 30 seconds,
do not remove the cable from the cache module. The cache module is backing up data. Data will
be lost if the cable is detached when the amber LED is still flashing.

Storage controller installation guidelines

To maintain optimal thermal conditions when installing an HP P-series Smart Array Controller or an HP HBA
option, HP recommends the following guidelines.
Install this storage
controller/HBA option
H240 adapter
P440 controller
P840 controller

Installing the storage controller and FBWC module options

To install the component:
Power down the server (on page 18).
1.
Remove all power:
2.
Disconnect each power cord from the power source.
a.
Disconnect each power cord from the server.
b.
Place the server on its side.
3.
Remove the access panel (on page 18).
4.
If installed, remove the PCI air baffle (on page 22).
5.
Remove the system air baffle (on page 23).
6.
If you intend to use an FBWC module, install the module on the storage controller.
7.
To prevent a server malfunction or damage to the equipment, do not add or remove
After the server is powered down, wait for 30 seconds, and then check the amber LED
In slot
Slot 3 or Slot 5
Slot 3 or Slot 5
Slot 3 or Slot 5
Using this cable option
HP Host Bus Adapter
Mini-SAS cable option
HP Smart Array Controller
Mini-SAS cable option
HP Smart Array Controller
Mini-SAS cable option
Hardware options installation 49