Controller Options - HP ProLiant DL385p User Manual

Hp proliant dl385p gen8 server user guide
Hide thumbs Also See for ProLiant DL385p:
Table of Contents

Advertisement

Remove the drive.
3.

Controller options

The server ships with an embedded Smart Array P420i controller. For more information about the controller
and its features, see the HP Smart Array Controllers for HP ProLiant Servers User Guide on the HP website
(http://bizsupport2.austin.hp.com/bc/docs/support/SupportManual/c01608507/c01608507.pdf). To
configure arrays, see the Configuring Arrays on HP Smart Array Controllers Reference Guide on the HP
website
(http://bizsupport1.austin.hp.com/bc/docs/support/SupportManual/c00729544/c00729544.pdf).
Upgrade options exist for the integrated array controller. For a list of supported options, see the QuickSpecs
on the HP website (http://www.hp.com/support).
The server supports FBWC. FBWC consists of a cache module and a capacitor pack. The DDR cache module
buffers and stores data being written by the controller. When the system is powered on, the capacitor pack
charges fully in about 5 minutes. In the event of a system power failure, a fully charged capacitor pack
provides power for up to 80 seconds. During that interval, the controller transfers the cached data from DDR
memory to flash memory, where the data remains indefinitely or until a controller retrieves the data.
CAUTION:
pinout. Do not use this controller with cache modules designed for other controller models,
because the controller can malfunction and you can lose data. Also, do not transfer this cache
module to an unsupported controller model, because you can lose data.
CAUTION:
the battery pack while an array capacity expansion, RAID level migration, or stripe size migration
is in progress.
CAUTION:
before unplugging the cable from the cache module. If the amber LED blinks after 15 seconds, do
not remove the cable from the cache module. The cache module is backing up data, and data is
lost if the cable is detached.
IMPORTANT:
error message is displayed when the server is powered up, indicating that the battery pack is
temporarily disabled. No action is necessary on your part. The internal circuitry automatically
recharges the batteries and enables the battery pack. This process might take up to four hours.
During this time, the cache module functions properly, but without the performance advantage of
the battery pack.
The cache module connector does not use the industry-standard DDR3 mini-DIMM
To prevent a server malfunction or damage to the equipment, do not add or remove
After the server is powered down, wait 15 seconds and then check the amber LED
The battery pack might have a low charge when installed. In this case, a POST
Hardware options installation 61

Advertisement

Table of Contents
loading

This manual is also suitable for:

Proliant dl385p gen8

Table of Contents