Cf_P-Mane Command; Cf_P-Manetime Command; Cf_On-Sta Command; Cf_Rcode Command - Sanyo PLC-XW250 - 2600 Lumens Manual

Expand serial command functional specifications
Hide thumbs Also See for PLC-XW250 - 2600 Lumens:
Table of Contents

Advertisement

PLC-XW200/250 Expand Serial Command Functional Specifications

8.10.14 CF_P-MANE Command

Command
"CF_Pÿ MANE_%1"[CR]
"OFF" --------------------------------- Set Power Management to OFF
"READY" ----------------------------- Set Power Management to Ready
"SHUTDOWN" --------------------- Set Power Management to Shut Down mode
"UP" ------------------------------ Switch Power management setting
%1
"DN" ------------------------------ Switch Power management setting
Set/Cancel Power Management
The status set by this command is stored in EEPROM and its setting is effective
Details
after ALL is OFF
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable

8.10.15 CF_P-MANETIME Command

Command
"CF_P-MANETIME_%1"[CR]
"01" ~ "30" ----------------------- Directly select setting time by the minute
"UP" ------------------------------- Plus one minute (01 → 02 → ÿ e ÿ e ÿ e → 30 → 01)
ÿ ÿ
"DN" ------------------------------- Minus one minute(30 → 29 → ÿ e ÿ e ÿ e → 01 → 30)
Set Power Management time
The status set by this command is stored in EEPROM and its setting is effective
Details
after ALL is OFF
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable

8.10.16 CF_ON-STA Command

Command
"CF_ONÿ STA_%1"[CR]
"ON" --------------------------- Set Power On Start to ON
"OFF" ------------------------- Set Power On Start to OFF
"UP" --------------------------- Switch setting (On → Off → On → ÿ e ÿ e ÿ e )
%1
"DN" --------------------------- Switch setting (On → Off → On → ÿ e ÿ e ÿ e )
Note) "UP" and "DN" behave the same.
Set/Cancel Power ON Start
The status set by this command is stored in EEPROM and its setting is effective
Details
after ALL is OFF
This command is available in normal Power ON status and "Network" is selected
in Standby mode of Setting menu .
Acceptable
Response
Unacceptable

8.10.17 CF_RCODE Command

Command
"CF_RCODE_%1"[CR]
"001" --------------------------- Select Code1
"002" --------------------------- Select Code2
"UP" --------------- Switch Code setting of Remote Control forward
%1
"DN" --------------- Switch Code setting of Remote Control backward
Select Code of Remote Control
Details
The status set by this command is stored in EEPROM and its setting is effective
ÿ Off → Ready → Shutdown → Offÿ
ÿ Off → Shutdown → Ready → Offÿ
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
(Code1 → Code2 → Code1 ...)
(Code2 → Code1 → Code2...)
34 / 64

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plc-xw250Plc-xw200

Table of Contents