Cr_Image Command; Cr_Imggmd Command - Sanyo PLC-XW250 - 2600 Lumens Manual

Expand serial command functional specifications
Hide thumbs Also See for PLC-XW250 - 2600 Lumens:
Table of Contents

Advertisement

PLC-XW200/250 Expand Serial Command Functional Specifications

9.4.13 CR_IMAGE Command

Command
"CR_IMAGE"[CR]
Get image setting status
Details
Required data "CUSTOM1" to "CUSTOM4" is the same as "Image1" to "Image4"
displayed when selecting IMAGE on OSD menu
Acceptable
%a
Response
Unacceptable

9.4.14 CR_IMGGMD Command

Command
"CR_IMGGMD"[CR]
Details
Get Image Gamma setting status
Acceptable
Response
%a
Unacceptable
"000_%a"[CR]
"DYNAMIC" --------------------------------------- Dynamic
"STAND" ------------------------------------------- Standard
"REAL" --------------------------------------------- Real
"CINEMA" ----------------------------------------- Cinema
"BLACKBOARD" -------------------------------- Blackboard
"COLORBOARD" -------------------------------- Colorboard
"CUSTOM1"~"CUSTOM4" -------------------- Image1~4
"Error Code"[CR] ---- When the command is invalid due to
condition such as Input source
"000_%a"[CR]
"DYN" ------------ Dynamic
"STD" ------------ Standard
"REL" ------------ Real
"CNM" ----------- Cinema
"BKB" ------------ Blackboard
"CLB" ------------ Colorboard
"Error Code"[CR]