Status Read Command; Format; Transfer Example; Operation Condition - Sanyo PLC-XW250 - 2600 Lumens Manual

Expand serial command functional specifications
Hide thumbs Also See for PLC-XW250 - 2600 Lumens:
Table of Contents

Advertisement

PLC-XW200/250 Expand Serial Command Functional Specifications

9. Status Read Command

9.1 Format

1)
PC issues commands in format as below:
"CR_Command" [CR]
Command : Character Line
2)
When projector receives the appropriate command, it returns a character line as the
required data
"000ÿ ? "%1 [CR]
%1: Required Data (Character Line. See [Basic Status Read Command Table])
3)
When the received data cannot be decoded, the projector returns "?"[CR]

9.2 Transfer Example

Get total dots of projector by Expand Commands
PC → PJ: "CR_TDOTS" [CR]
PC ← PJ: "000_1344" [CR]

9.3 Operation Condition

1) Basically Status Read Commands should be always operated.
2) When Eco mode is selected in Standby mode of Setting menu and projector is in Standby,
Status Read Commands are invalid.

9.4 Image Status Read Command

9.4.1

CR_BRIGHT Command

Command
"CR_BRIGHT"[CR]
Details
Get Brightness value of user control
Acceptable
Response
Unacceptable
9.4.2

CR_CONT Command

Command
"CR_CONT"[CR]
Details
Get Contrast value of user control
Acceptable
Response
Unacceptable
"000_ÿ ÿ A
"[CR]
%a
"000"~"063"
"Error Code"[CR]
"000_ÿ ÿ A
"[CR]
%a
"000"~"063"
"Error Code"[CR]