Mounting Options - ADTRAN Vanta 1335 Hardware Installation Manual

Table of Contents

Advertisement

Unit Installation

Mounting Options

The unit may be installed in rackmount, wallmount, or tabletop configurations. The following sections provide
step-by-step instructions for rack mounting and wall mounting.
Rack Mounting the NetVanta
The NetVanta is a 1U-high, rack-mountable unit that can be installed into a 19-inch equipment rack. The
following steps guide you in mounting the NetVanta into a rack.
If installed in a closed or multi-unit rack assembly, the operating ambient temperature
of the rack environment may be greater than room ambient temperature. Therefore,
consideration should be given to installing the equipment in an environment compatible
with the maximum ambient temperature specified by the manufacturer.
Installation of the equipment in a rack should be such that the amount of air flow
required for safe operation of the equipment is not compromised.
Be careful not to compromise the stability of the equipment mounting rack when
installing this product.
Consideration should be given to the connection of the equipment to the supply circuit
and the effect that overloading the circuit might have on overcurrent protection and
supply wiring. Appropriate consideration of equipment nameplate ratings should be
used when addressing this concern.
Reliable grounding of rack-mounted equipment should be maintained. Particular
attention should be given to supply connections other than direct connections to the
branch circuit (e.g., use of power strips).
Step
1
To allow proper grounding, scrape the paint from the rack around the mounting holes where the
NetVanta will be positioned.
2
Position the NetVanta in a stationary equipment rack. This unit occupies 1U of space.
3
Have an assistant hold the unit in position as you install two mounting bolts through the unit's
brackets and into the equipment rack using a #2 Phillips-head screwdriver.
4
Apply power to the unit (refer to
Wall Mounting the NetVanta
By following these instructions exactly, the NetVanta can be safely mounted on the wall.
To avoid damaging the unit, use only the screws included in the shipment when
attaching mounting ears to the chassis.
When wall mounting the NetVanta, care must be taken not to damage the power cord.
Do not attach the power cord to the building surface or run it through walls, ceilings,
floors, or openings in the building structure.
The socket-outlet must be installed near the equipment and must be easily accessible.
40
Instructions for Rack Mounting the NetVanta
Supplying Power to the Unit on page
Copyright © 2011 ADTRAN, Inc.
NetVanta 1335 Series Hardware Installation Guide
Action
41).
61700515E2-34C