Installing A Passive Cpu Heatsink - Supero SuperServer 6016T-MTHF User Manual

1u rackmount server
Table of Contents

Advertisement

Installing a Passive CPU Heatsink

Two different CPU heatsinks are used in the 6016T-MTHF/6016T-MHLF. SNK-
P0041 is for the CPU toward the front (closest to the hard drives) and SNK-P0037P
is for the CPU nearer to the back of the server. The procedure below applies to
both heatsinks.
Notes: The serverboard comes
with a heatsink bracket pre-in-
stalled on the reverse side of the
board. Do not apply any thermal
grease to the heatsink or the CPU
die; the required amount has al-
ready been applied.
1. Place the heatsink on top
of the CPU so that the four
mounting holes are aligned
with those on the retention
mechanism.
2. Install two diagonal screws
(i.e. the #1 and the #2
screws) and tighten them until
just snug (do not fully tighten
the screws to avoid damaging
the CPU.)
3. Repeat step 2 with the #3
and #4 screws. Make sure all
screws are snug.
Chapter 5: Advanced Serverboard Setup
Screw#1
Screw#1
Install Screw#1
Screw#1
5-7
Screw#4
Screw#3
Screw#2
Screw#2
Install Screw#2