Download Print this page

Allied Telesis 86222-27 Release Note page 41

Patch for rapier switches

Advertisement

Patch 86222-27 For Rapier Switches
Example
See Also
Syntax
Description
Example
See Also
Syntax
Description
Figure 1: Example output from the SHOW IP ICMPREPLY command:
SHOW IP ICMP REPLY MESSAGES
--------------------------------------------------------------------------------
ICMP REPLY MESSAGES:
Network Unreachable ................ disabled
Host Unreachable ................... disabled
Redirect ........................... enabled
--------------------------------------------------------------------------------
Patch 86222-27 for Software Release 2.2.2
C613-10319-00 REV Z
If ALL is specified, all configurable ICMP message replies are disabled. If
NETUNREACH is specified, all network unreachable message replies are
disabled (RFC792 Type 3 Code 0). If HOSTUNREACH is specified, all host
unreachable message replies are disabled (RFC792 Type 3 Code 1). If
REDIRECT is specified, all ICMP redirect message replies are disabled (RFC792
Type 5 Code 0, 1, 2, 3).
To disable all configurable ICMP messages, use the command:
DISABLE IP ICMPREPLY=ALL
ENABLE IP ICMPREPLY
DISABLE IP ECHOREPLY
SHOW IP ICMPREPLY
ENABLE IP ICMPREPLY
ENABLE IP
ICMPREPLY[={ALL|NETUNREACH|HOSTUNREACH|REDIRECT}]
This command enables ICMP reply messages.
If ALL is specified, all configurable ICMP message replies are enabled. If
NETUNREACH is specified, all network unreachable message replies are
enabled (RFC792 Type 3 Code 0). If HOSTUNREACH is specified, all host
unreachable message replies are enabled (RFC792 Type 3 Code 1). If
REDIRECT is specified, all ICMP redirect message replies are enabled (RFC792
Type 5 Code 0, 1, 2, 3).
To enable all configurable ICMP messages, use the command:
ENABLE IP ICMPREPLY=ALL
ENABLE IP ECHOREPLY
DISABLE IP ICMPREPLY
SHOW IP ICMPREPLY
SHOW IP ICMPREPLY
SHOW IP ICMPREPLY
This command display the status of configurable ICMP messages (Figure
41