Processor Switch Settings; Specifications - HP D5970A - NetServer - LCII Service & Reference Manual

Hp netserver service handbook, volume 1 - low end
Hide thumbs Also See for D5970A - NetServer - LCII:
Table of Contents

Advertisement

The switches and each of their definitions are listed below.
Switch
Factory
position
preset
1
OFF
2
3
OFF
4
OFF
(See table
5 - 8
below)

Processor Switch Settings

The following table shows the settings for each Intel processor module. To set the switches correctly,
observe the markings on the replacement processor module. Each processor module will have a speed
marking. Use the table below to look up the appropriate switch settings for each of these CPUs.
CPU Speed
Switch 5
400 MHz
OFF
450 MHz
ON
500 MHz
OFF

Specifications

Temperature
Operating
Non-operating
Humidity (non-condensing)
Operating
Non-operating
Altitude
Operating
Non-operating
Thermal Output
Maximum Operating
70
Off - let's you power on your system by pressing any key on the keyboard
or the power-on button.
On – let's you power on the system only by pressing the power-on button.
Unused
Clears the password. Set the switch to the ON position and restart the
NetServer to clear the password. Return the switch to the OFF position and
restart the NetServer to return to normal operation.
Resets the CMOS configuration to the default values. Set the switch to the
ON position and restart the NetServer to reset the CMOS. Return the switch
to the OFF position and restart the NetServer to return to normal operation.
Select processor speed settings. The switch positions may need to be
changed when upgrading the processor (see table below).
Switch 6
Switch 7
OFF
ON
OFF
ON
ON
ON
5 to 35 C (41 to 95 F)
-40° to +65° C (-40° to +149° F)
20% to 80% relative humidity, non-condensing
5% to 95% relative humidity, non-condensing
-30 to 3,000 m (~ 10,000 ft)
-30 to 12,000 m (~ 40,000 ft)
1116 BTU/hr
Definition:
Switch 8
OFF
OFF
OFF