Replacement Procedure

A
Check that the p light on the Operation panel is lit.
If the p light is flashing, the printer is operating. Wait until operation has stopped.
B
For the Dual Roll Model, hold down the handle of the front roll paper feeder a little, press the Lock Release
button, and then raise the front roll paper feeder.
When the roll paper feeder is raised, a warning buzzer sounds.
C
Place your hand under the maintenance tank cover to open the cover.
D
Remove the maintenance tank.
See the following for information on disposing of a used maintenance tank.
U "Disposing of the Main Printer Unit and Consumables" on page 19