HP C8000 - Workstation - 0 MB RAM Installation Instructions Manual page 7

Mid-weight slide kit
Hide thumbs Also See for C8000 - Workstation - 0 MB RAM:
Table of Contents

Advertisement

3.
Using the marked mid-weight slide-mounting alignment tool,
mark the front and rear columns of the rack.
Item
Description
1
Mark for HP 5U servers
2
Mark for HP 4U servers
3
Mark for HP 2U and HP 3U servers
4.
Remove the top pin from the mid-weight outer slide assemblies.
NOTE: All M5 screws must be torqued to 6.2 Nm (55 lb).
5.
Install the M5 barrel nuts on the rack columns.
6.
Install the mid-weight outer slide assemblies by aligning the
center pin of the mid-weight outer slide assemblies with the
markings on the front and rear of the rack columns.
7.
Screw the M5 x 30-mm screws to the mid-weight outer slide
assemblies to secure it to the rack.
WARNING: Two people are needed to align and install
the server properly. Do not install the server with the mid-
weight inner slides extended.
8.
Slide the server into the mid-weight outer slide assemblies.
9.
Connect the cables to the server.