Nortel BCM 4.0 Upgrade Manual page 15

Business communications manager
Hide thumbs Also See for BCM 4.0:
Table of Contents

Advertisement

Ensure mapped drives are disconnected: Remove any mapped drives connected to the
BCM 3.6/3.7 systems using the Maintenance Tools web page.
Ensure next hop router IP address belongs to the same subnet as the static routes: The
next hop router IP address for static routes in BCM 3.6/3.7 is validated during the upgrade to
BCM 4.0. This means that the next hop router IP address must belong to the same subnet as
the interface to which it is added, otherwise the static route is not upgraded to BCM 4.0.
For example: Static routes are configured on LAN1 interface with IP address of 172.17.22.10
Route 1:
Destination address: 1.1.1.1
Destination mask: 255.255.255.0
Next hop: 172.17.22.20
Metric: 1
On BCM 4.0, route 1 is added and route 2 is deleted since the next hop, 10.20.30.40, does not
belong to same subnet as LAN1.
Confirm that the voice inventory service is running: To avoid potential errors about the
MSC core telephony software, the media services processor expansion cards (MS-PEC), and
the type of MSC, you must confirm that the voice inventory service is running. In Unified
Manager, select System, then select Tools > Perform System Inventory from the top menu.
Finally select Tools > Display System Inventory. If the service is running correctly, exit
Unified Manager. If the service is not running correctly, reboot the BCM system. Once the
system is running again, display the inventory again to confirm that the service is now running.
Ensure no overlapping subnets in IPSec branch office tunnel accounts: In BCM 3.6/3.7
you can configure an IPSec branch office tunnel where IP subnets in the local accessible
networks overlap the IP subnets in the remote accessible networks. This is not supported in
BCM 4.0. If an IPSec branch office tunnel account has overlapping subnets, this account will
not exist after the upgrade to BCM 4.0.
Before upgrading your system from BCM 3.6/3.7 to BCM 4.0, make sure there are no
overlapping subnets between the local and remote accessible networks in any of your IPSec
branch office tunnel accounts.
Upgrade IVR application: If your site uses IVR, you must upgrade IVR before upgrading to
BCM 4.0 software. Refer to your IVR upgrade guide for more detailed information.
Prepare Reporting for Contact Center (RCC): Immediately before running the Upgrade
Wizard, perform the following steps to retain your RCC data:
1
Disable all skillsets and log out all agents from the call center.
2
Ensure all calls have exited the call center skillsets.
3
Ensure that RCC has downloaded all the data from the BCM and a complete pre-upgrade
record is available.
4
Backup the RCC database on the Web Host PC. The backup location is:
• For RCC versions 2.3.209 and later, the backup location is: C:\Program
Files\MySQL\MySQL Server 4.1\data\CCRDB.
• For RCC versions earlier than 2.3.209, the backup location is C:\MySQL\data\CCRDB.
Chapter 2 Pre-upgrade activities
Route 2:
Destination address: 2.2.2.2
Destination mask: 255.255.255.0
Next hop: 10.20.30.40
Metric: 1
15
Upgrade Guide

Advertisement

Table of Contents
loading

Table of Contents