Cisco VG30D User Manual page 44

Voice gateway
Hide thumbs Also See for VG30D:
Table of Contents

Advertisement

General
Major indicates an event that will cause calls to fail. In some cases, remedial action is possible and
should be attempted before contacting your supplier.
Minor indicates an event that may have caused a single call or few calls to fail.
Informational indicates an event that contains information that may be useful but does not require any
action.
Content in
Table 5-1
System Log Events
Error Code
Log Description
1
Internal error,
Gateway will
reboot.
2
Watchdog timeout
400
System is starting
600
Reboot requested
by user
601
Recovered from
SCN fatal error
602
The application
configuration has
been reset to
default values
603
A user has logged
in to Web
management
Cisco VG30D Voice Gateway User Guide
5-2
Table 5-1
appears in order of error code number.
Seriousness
Critical
Critical
Informational
Informational
Critical
Informational
Informational
Meaning
Automatic Action
A software error
The gateway
occurred from
restarts and an
which the gateway
entry gets written
could not recover.
to the log.
A software error
The gateway
occurred from
restarts and an
which the gateway
entry gets written
could not recover.
in the log.
The gateway
An entry gets
restarted due to
written to the log
power on, or
and an SNMP trap
software error, or
gets generated.
reboot requested
by user.
The user requested
The gateway
that the gateway be
restarts, an entry
restarted.
gets written to the
log, and an SNMP
trap gets
generated.
A software error
The gateway
occurred from
restarts, and an
which the gateway
entry gets written
could not recover.
to the log.
The user requested
The configuration
that the Gateway
gets reset to
configuration be
factory default, an
reset to factory
entry gets written
default.
to the log, and an
SNMP trap gets
generated.
The IP address of
An entry gets
everyone who
written to the log
logged into the
and an SNMP trap
gateway's
gets generated.
management
system is recorded.
Chapter 5
Diagnostics
User Action
Report problem to
your supplier.
Report problem to
your supplier.
None
None
Report problem to
your supplier.
None
None.
OL-19276-01

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents