Error List - Canon SX50 - REALiS SXGA+ LCOS Projector Command Reference Manual

Realis command codes
Hide thumbs Also See for SX50 - REALiS SXGA+ LCOS Projector:
Table of Contents

Advertisement

10. Error List

Code
Error character string
Item
TYPE
1
0001
e
BAD_SEQUENCE
2
0002
e
INVALID_COMMAND
3
0003
e
INVALID_MODE
4
0004
e
INVALID_FORMAT
5
0005
e
NOT_POWER_SUPPLIED
6
-
i
BUSY
7
000A
e
INVALID_PARAMETER
000B
JOB_TIMEOUT
8
e
USER_COMMAND_VERSION_IS_UPDA
9
-
w
TED
F001
SYSTEM (UNKNOWN)
10
e
11
E0XX
e
COMMUNICATION_ERROR
12
200X
e
INVALID_SOURCE (****)
2010
e
NO_SIGNAL
13
201X
e
INVALID_SIGNAL (****)
i
BUSY (NOW_SETTING)
BUSY
14
-
i
(POWER_MANAGEMENT_READY)
i
BUSY (INTERNAL_PROCESS)
0801
15
e
INVALID_VALUE
0802
1001
e
TERMINAL_OUT
16
1002
e
NO_LOGO_CAPTURED
1003
IP_NOT_AVAILABLE
e
203X
e
INVALID_RESOLUTION (***)
※ The error code is expressed as a four-digit hexadecimal character string. 'X' is a number from '0' to '9' or letter from 'A' to 'F'.
※ Errors with the newer item numbers have higher priority. (When there is more than one error, the highest level error is returned. However, error priority is
the same within the same item number.)
Error description
Communication sequence error
Command is invalid (undefined).
The designated command cannot be
executed in this mode.
The command format is incorrect.
Power is not being supplied.
Transition between states or processing is in
progress in the SX50.
The parameter (type) is invalid (undefined).
This includes the case when the number of
parameters is incorrect.
SX50 internal processing has timed out.
The user command version is being updated.
An internal error occurred.
A communication protocol violation occurred
in the projector.
This cannot be executed with the current input
source.
The current input source is indicated in
parentheses.
There is no signal input.
This cannot be executed with the current input
signal.
The current input signal is indicated in
parentheses.
Signal setting (detection) is in progress.
Preparing to switch to power management
standby.
Heavy processing is in progress.
Numerical parameters are invalid or outside
the range.
The input cannot be selected since the
terminal is set to output.
Processing cannot be executed since the user
image is not registered.
IP conversion cannot be performed.
The input signal resolution is not correct.
Remedy
Wait until the response is received to send the
command.
Send the correct command.
Switch the mode using the REMOTE or
LOCAL command.
Send in the correct command format.
Use the POWER ON command to turn on the
power.
Wait until the power supply state changes to
"ON", "OFF", or "PMM".
Use the correct parameter(s).
Resend the command.
Use GET COMVER to obtain the latest user
command version.
Resend the command.
Resend the command.
Change the input source.
Input the signal.
Change the input signal.
Wait until the processing is completed.
Use the RANGE command to obtain the
parameter range, and then use a parameter
within the range.
Use the TERMINAL command to set the
terminal to input, and then select the input
again.
Register the user image.
Change to the correct input signal.
Change to the correct resolution of the input
signal.