Commands
PMM
Function Power management
Parameter
Parameter
STANDBY
The RANGE command can be used to obtain the parameter range that can be set at that time.
Response An 'i:OK' is returned after setting is successful.
Description This sets Power Management mode.
(1) This command is identical to the Power management mode function in the System settings menu.
(2) The Power Management function is disabled when the SX50 is in Remote mode even if Power management
mode is set to Exit mode or Standby mode.
(It is enabled in Local mode only.)
(3)
The GET command can be used to retrieve the current Power Management mode.
Example Setting
> PMM=STANDBY
< i:OK
Reference
> GET PMM or ?PMM
g:PMM=EXIT
<
Obtain settable parameters
> RANGE PMM
< r:PMM=I,OFF,STANDBY,EXIT
※Commands are indicated by ">", and responses are indicated by "<"
Supported Command States
Power supply
OFF
ON
PM
D-RGB
A-RGB1 A-RGB2
×
×
○
○
○
※If a state is not supported, "INVALID_MODE" or "NOT_POWER_SUPPLIED" is returned with the Err response.
※When the power supply state is in the process of switching, an "i:BUSY" reply may be sent.
Meaning
OFF
OFF
Standby mode
EXIT
Exit mode
Input
Comp
Video
S-Video
○
○
○
○
This sets the Power Management mode to "Standby" mode.
This retrieves the Power Management mode.
Mode
None
Remote
Local
×
○
○
Mode
Control Setting
Reference
ID