Description
Value Range
Default Value
CODEC_G711_REQ
Value Format
Description
Value Range
Default Value
CODEC_G729_PARAM
Value Format
Description
Value Range
Default Value
Document Version
2010-08
Specifies the payload type number with "SDP_PTYPEx_y" for the
corresponding encoding name specified by "SDP_CODECx_y" (x:
priority, y: line number).
0–127, 255
Note
•
If an empty string is set for "SDP_CODECx_y", "255" must be
set as the value for the corresponding "SDP_PTYPEx_y".
9 (for SDP_PTYPE0_1 to SDP_PTYPE0_8)
8 (for SDP_PTYPE1_1 to SDP_PTYPE1_8)
2 (for SDP_PTYPE2_1 to SDP_PTYPE2_8)
18 (for SDP_PTYPE3_1 to SDP_PTYPE3_8)
0 (for SDP_PTYPE4_1 to SDP_PTYPE4_8)
Integer
Specifies whether to set "PCMU" as a codec selection automatically
when "SDP_CODECx_y" (x: priority, y: line number) is set to any codec
selection other than "PCMU".
Note
•
Changing this setting may require restarting the unit.
•
0 (Do not set "PCMU")
•
1 (Set "PCMU")
1
Integer
Specifies whether to add an attribute line, "a=fmtp:18 annexb=no", to
SDP when "SDP_CODECx_y" (x: priority, y: line number) is set to
"G729A".
Note
•
Changing this setting may require restarting the unit.
•
0 (Do not add "a=fmtp:18 annexb=no")
•
1 (Add "a=fmtp:18 annexb=no")
0
4.6.1 Codec Settings