HP P3410A - NetRAID 1M RAID Controller User Manual page 86

Hp netraid series user guide
Hide thumbs Also See for P3410A - NetRAID 1M RAID Controller:
Table of Contents

Advertisement

Chapter 4
For optimal performance of RAID 5 logical drives, use separate
adapters to control arrays with three physical drives and arrays with
four or more physical drives.
Change Disk Geometry: Changes the layout of logical drives presented to
the NOS. The default setting is 8 GB, and the alternative is 2 GB. Different
operating systems use different disk geometries. Your NOS documentation
may indicate the disk geometry it uses.
NOTE
Changing the disk geometry setting only changes the geometry
of logical drives created after the change. It does not change
the geometry of existing logical drives.
Disk Spin-Up Timings: Sets the method and timing for spinning up the
hard disk drives in the HP NetServer. The default setting is Automatic.
Cache Flush Timings: Sets the cache flush interval to once every 2, 4, 6,
8, or 10 seconds. The default setting is 4 seconds.
View/Update Rebuild Rate: View or change the Rebuild Rate for the
adapter.
Diagnostics: The hardware diagnostic tool performs the following
hardware tests:
On-board memory test
NVRAM test
Parity check
DMA test
Timer test
Interrupt test
Hardware register test
Adapter Type: Displays the adapter type: HP NetRAID-1Si,
HP NetRAID-3Si, or integrated HP NetRAID.
Emulation: Sets PCI class code to I2O (for I
Storage (for conventional non-I
Mass Storage.
Autorebuild: Enables or disables the Autorebuild parameter. For complete
information, see "Rebuilding Data" in Chapter 5 in this guide.
80
HP NetRAID Express Tools
O operation) or Mass
2
O mass storage). The default setting is
2

Advertisement

Table of Contents
loading

Table of Contents