Chapter 5
You installed a replacement drive in a different physical slot from the
failed drive.
A logical drive of RAID level 0 shared space on the drive that needs to be
rebuilt.
To rebuild drives manually, you must have a Ready drive of equivalent size. The
HP NetRAID system will not rebuild data onto a hot spare when you initiate the
rebuild manually.
You can select Manual Rebuild from all HP NetRAID management utilities.
Manual Rebuild from HP NetRAID Assistant (under Microsoft Windows NT or
Windows 2000)
1. Start HP NetRAID Assistant.
2. Choose Physical Drives from the Main menu.
3. Select the Rebuild option. Select Cancel to stop the rebuild process at any
time. The drive will return to its original status before the rebuild began.
4. To check the progress of the rebuild, choose Progress from the Main
menu, then select Rebuild Progress.
Manual Rebuild from HP NetRAID Config (under Novell NetWare, IBM OS/2, SCO
OpenServer, or SCO UnixWare)
Using HP NetRAID Config, you can rebuild drives individually or in batch mode.
Manual Rebuild of an Individual Drive from HP NetRAID Config
1. Start HP NetRAID Config by using the command appropriate for your
network operating system.
2. Choose Objects from the Management menu.
3. Choose Physical Drive from the Objects menu. A device selection
window is displayed showing all physical drives.
4. Use the arrow keys to highlight the physical drive that has failed, and press
Enter.
5. Select the Rebuild option. Press Esc to stop the rebuild process at any
time. The drive will return to its original state before the rebuild began.
Manual Rebuild Using Batch Mode from HP NetRAID Config
1. Start HP NetRAID Config by using the command corresponding to your
network operating system.
Reconstructing and Rebuilding Drives