Drivers for the card have already been installed.
There are no drivers associated with the slot.
The green power LED is steady
the pdweb tool to power the slot
The yellow attention LED if steady
Refer to the host bus adapter (HBA) documentation for details on card installation.
Run the olrad -q command to determine the status of all the PCI I/O slots.
Obtain a copy of the interface card guide for instructions on preparing the operating system for the online
addition of the PCI I/O card before attempting to insert a PCI I/O card into the PCI-X card cage assembly
backplane slot.
Observe all ESD safety precautions before attempting this procedure. Failure to follow ESD
CAUTION
safety precautions could result in damage to the server.
This procedure describes how to perform an online addition of a PCI card using the attention button for
cards whose drivers support online add or replacement (OLAR). The attention button is also referred to as the
doorbell.
Step 1. Remove the top cover.
Step 2. Remove the PCI bulkhead filler panel.
Step 3. Flip the PCI manual retention latch (MRL) for the card slot to the open position. Refer to
Figure 3-8.
Step 4. Install the new PCI card in the slot.
NOTE
Step 5. Flip the PCI MRL for the card slot to the closed position.
CAUTION
Step 6. Press the attention button.
Chapter 3
. Should the empty slot be in the
OFF
.
OFF
or is blinking if a user has requested the slot location.
OFF
A slow, firm pressure is needed to properly seat the card into the backplane.
Working out of sequence or not completing the actions within each step could cause
the system to crash.
Do not press the attention button until the latch is locked.
Installing Additional Components
PCI-X Card Cage Assembly I/O Cards
state use the olrad command or
ON
59