HP A7533A - Brocade 4Gb SAN Switch Base Release Note page 52

Hp storageworks fabric os 6.2.1 release notes (5697-0275, december 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

VEX port receives bad SFID and frame cannot be routed to translate
domain due to continuous RTWR retries from backbone fabric where
fabricshow is missing IP address.
E-Port Class Link Resets are not fencing. RASLOG message will be
presented indicating link resets are above threshold, but the port will
not have been fenced as expected.
RNID data reporting same serial number for two different logical
switches in FICON environment, as user entered FRU number via CLI
is not being modified.
Detected termination of process fabricd:4120 followed by software
verify errors due to HP StorageWorks DC SAN Director being unre-
sponsive.
Partitioned HP StorageWorks DC04 Director in FICON environment
panicked after reset allegiance issued by multiple hosts, leading to
FICUD terminating and switch reboot.
SNMPd panics and generates a core file that can fill up the root file
system. User will observe snmpd process being killed and Detected
termination of process error message.
Node descriptors missing from FICON RNID data for HP StorageWorks
DC SAN Director and HP StorageWorks DC04 Director.
Tape pipelining code randomly sends only data frames in an exchange
to a tape drive over an FCIP link, leading to tape job failure.
Port swap does not work for ports 32—47 on 48-port blade via the
GUI for FICON.
Registered Link Incident Records (RLIR) with Loss of Light (LOL) are being
generated on 8 Gb channels during CEC Initial Machine Load (IML)
in FICON environment.
Tape pipelining code does not close exchange upon an ELS RJT re-
sponse to REC -- invalid oxid/rxid combo causing write se-
quence failures. Tape reads are unaffected.
Fibre Channel FastWrite (FCFW) corrupts buffer pool upon Turbo Write
Block (TWB) allocation failure on Proxy Initiator leading to I/O failure.
With HP StorageWorks DC SAN Director, Web Tools shows high host
CPU usage (approximately 80%) when port configuration operation
is performed on a large system. CPU usage goes back to normal once
operation completes.
Supportsave may show parity errors on disabled ports on a switch
that has been upgraded from a lower code level to Fabric OS 6.1.2
and never cold booted. No errors will be caused on enabled ports,
or after a disabled port is enabled.
When a blade is hot plugged into an HP StorageWorks DC SAN
Director or HP StorageWorks DC04 Director, its information will not
appear in the embedded GUI.
Lossless DLS failed with dropped frame causing IFCC in presence of
ICLs.
52
Fixed in Fabric OS 6.2.0e
Fixed in Fabric OS 6.2.0e
Fixed in Fabric OS 6.2.0e
Fixed in Fabric OS 6.2.0e
Fixed in Fabric OS 6.2.0e
Fixed in Fabric OS 6.2.0e
Fixed in Fabric OS 6.2.0e
Fixed in Fabric OS 6.2.0e
Fixed in Fabric OS 6.2.0e
Fixed in Fabric OS 6.2.0e
Fixed in Fabric OS 6.2.0e
Fixed in Fabric OS 6.2.0e
Fixed in Fabric OS 6.2.0e
Fixed in Fabric OS 6.2.0e
Fixed in Fabric OS 6.2.0e
Fixed in Fabric OS 6.2.0e

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ae370a - brocade 4gb san switch 4/12

Table of Contents