Detected termination of 0.weblinker.fcg on HP StorageWorks
DC04 SAN Director and messages like KSWD-1002, 5766, SLOT
4 | FFDC | CHASSIS, WARNING displayed on the console.
After enabling Virtual Fabrics via DCFM on HP StorageWorks 8/40
SAN Switch, some ports may be disabled.
Missing FICON interrupt on HP StorageWorks DC04 SAN Director
due to CUP not responding in time before channel timed out.
Security commands such as fddcfg -fabwideset fail with RCS
transaction error.
When performing firmwareupgrade from Fabric OS 6.1x to 6.2.0
then reverting back to 6.1.x via firmwarerestore, the downgrade
fails and leaves the CP with unrecoverable passwords, leaving it in
an inconsistent state where the user may not be able to login.
Disconnecting/reconnecting an ISL on the HP StorageWorks Encryption
SAN Switch while a rekey operation is in progress may result in failure
of new key creation. LUN state shows Rekey ACK timeout.
CP panicked with FICUD crash and rebooted during supportsave.
If ISL links between two encryption cluster nodes are continuously dis-
connected/reconnected during rekey operations, one of the LUNs can
hang at LUN discovery state.
LUNs in a container show target offline, leading to the host no longer
having access to their LUNs through the crypto target containers.
With tape pipelining active, the switch may return a good status without
sending data, leading to tape I/O failure/errors.
The host detects IFCC errors to CUP port.
HP StorageWorks Encryption SAN Switch went faulty when starting
traffic, which let to loss of LUNs to the host.
Taking SKM down while rekeys are in progress causes a LUN to get
stuck in Not ready (Key creation) state.
When attempting to swap ports from the Web Tools GUI, the operation
may fail due to an HTTP 500 error.
Default SNMP v3 values set differently in different Fabric OS releases
leading to the mibcapability option of snmpconfig not being
able to control ficon mib.
In Access Gateway mode, if the second FDISC comes in before the
switch responds to the first FDISC between the same pair of devices,
the Access Gateway panics, triggering a reboot.
50
Fixed in Fabric OS 6.2.0d
Fixed in Fabric OS 6.2.0d
Fixed in Fabric OS 6.2.0d
Fixed in Fabric OS 6.2.0d
Workaround prior to upgrade: Once
passwords are blocked, boot into
single user mode and reset system
passwords.
Fixed in Fabric OS 6.2.0d
Fixed in Fabric OS 6.2.0d
Workaround prior to upgrade: After
enabling FMSMODE for the first time,
do
switchdisable/switchenable
- hafailover - hareboot -
reboot.
Fixed in Fabric OS 6.2.0d
Fixed in Fabric OS 6.2.0d
Fixed in Fabric OS 6.2.0d
Fixed in Fabric OS 6.2.0d
Fixed in Fabric OS 6.2.0d
Fixed in Fabric OS 6.2.0d
Fixed in Fabric OS 6.2.0d
Fixed in Fabric OS 6.2.0d
Fixed in Fabric OS 6.2.0d
Fixed in Fabric OS 6.2.0d