USB port LED of HP StorageWorks DC SAN Backbone Director CP
blade stays ON after HA failover.
CUP Port stuck in Contingent Allegiance State after z9 Host IPL.
Spinfab and porttest (diagnostics) are not supported on ICL ports.
Bogus core_file created and transferred after the first reboot after a
firmwaredownload.
B-series Multi-protocol (MP) Router blades in HP StorageWorks DC
SAN Backbone Director chassis may fail sysverification tests.
With a switch in Interop Mode 2 or 3, the Zoning configuration is not
being included in configupload.
FICON Channel continuously sends RRQ frames for approximately 20
seconds before aborting.
If QoS and Diff Serv are enabled, some FCIP tunnels may not come
online in the case of an 8 to 1 fan-in scenario.
Under rare conditions, fabric mode Top Talkers monitor does not dis-
play correct flow values.
Attempting to configure port mirroring on a director with both 4Gb
and 8Gb blades may result in a software Verify error.
In rare instances the Name Server DB is out of sync between FOS and
EOS switches in interop mode 3.
Seccertutil show does not display the contents of certificates with
.cer extension.
When resetting all the hosts on a blade or slotpoweroff on a blade,
HP StorageWorks 4/256 SAN Director CP reboots due to the Software
Watchdog detecting unexpected termination of the Name Server
daemon.
Fastboot causes unnecessary FFDC, ERROR, ..., libipadm:
em_AdmSwitchNameGet()
In some instances of congestion in the Ethernet network, the displayed
VE port utilization value is incorrect.
36
Fixed in Fabric OS 6.2.0
Fixed in Fabric OS 6.2.0
Fixed in Fabric OS 6.2.0
Fixed in Fabric OS 6.2.0
Fixed in Fabric OS 6.2.0
Workaround prior to upgrade:
Rerun system verification.
Fixed in Fabric OS 6.2.0
Fixed in Fabric OS 6.2.0
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Port disable/enable the VE-Port
Fixed in Fabric OS 6.2.0
Fixed in Fabric OS 6.2.0
Fixed in Fabric OS 6.2.0
Workaround prior to upgrade:
After locating the device ID, disable
and then enable that device.
Fixed in Fabric OS 6.2.0
Workaround prior to upgrade:
Only LDAP certificates with .cer ex-
tension is supported; so use the
--ldapcert option for importing
.cer certificates.
Fixed in Fabric OS 6.2.0
Fixed in Fabric OS 6.2.0
Fixed in Fabric OS 6.2.0
Workaround prior to upgrade:
Use portperfshow command.