HP A7533A - Brocade 4Gb SAN Switch Base Release Note page 40

Hp storageworks fabric os 6.2.1 release notes (5697-0275, december 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

No F_RJT's being returned for class 2 frames that are not routable ac-
cording to a QoS/TI configuration.
B-series Multi-protocol Router blade failed to do blade firmwaredown-
load.
Switch reboots when IFL is enabled.
Frame drop observed after creating a TI zone with failover enabled
in the backbone fabric ( TI over FCR).
Hard Zoning disabled when ports toggle.
Pathinfo doesn't match urouteshow and rtedebug.
Sensors show incorrect command output in fully loaded HP Storage-
Works DC SAN Backbone Director.
Update to VC assignment scheme within core ASIC management
structure.
Fast Write performance issue with a particular FCIP Ex_Port configur-
ation.
Under Port Base Routing, topologyshow always shows None for the
In Port field on HP StorageWorks 8/8, 8/24, and 8/40 SAN Switches.
HCL on switch continues if sent Pause frame is rejected by attached
M-EOS switch. HCL on switch will sometimes continue, even when a
sent Pause frame is rejected by another switch in the fabric.
N_Port on Edge_AG_200E_PG got disabled with reason code Initi-
ator/target connected to N-Port.
Firmware download of Fabric OS 6.1.0 is allowed on an embedded
blade that should not allow it.
Fabric Rebuild during HP StorageWorks 8/40 SAN Switch HCL when
1 of 2 Backbones connect to a M6140 director.
If Turboramtest is performed, the Telnet console will disconnect.
Incorrect error when changed switchname for more than 24 charac-
ters through CLI in FMS mode.
F_Ports on HP StorageWorks 8/8 and 8/24 SAN Switches AG cannot
login, and become G_Ports.
40
Fixed in Fabric OS 6.2.0
Fixed in Fabric OS 6.2.0
Workaround prior to upgrade:
Perform slot power off / slot power
on the blade that timed out.
Fixed in Fabric OS 6.2.0
Fixed in Fabric OS 6.2.0
Fixed in Fabric OS 6.2.0
Fixed in Fabric OS 6.2.0
Fixed in Fabric OS 6.2.0
Fixed in Fabric OS 6.2.0
Fixed in Fabric OS 6.2.0
Workaround prior to upgrade:
Disable FCR routing and Ex_Ports and
merge the fabric into one large fabric.
Fixed in Fabric OS 6.2.0
Workaround prior to upgrade:
Use urouteshow to view the 'Out
Port' selected for a particular 'In Port'
to a domain when using Port Based
Routing.
Fixed in Fabric OS 6.2.0
Fixed in Fabric OS 6.2.0
Fixed in Fabric OS 6.2.0
Fixed in Fabric OS 6.2.0
Fixed in Fabric OS 6.2.0
Fixed in Fabric OS 6.2.0
Fixed in Fabric OS 6.2.0.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ae370a - brocade 4gb san switch 4/12

Table of Contents